User manual
Building In
min. 550
20
600
min. 560
591
598
594
114
19
21540
570
558
min. 550
20
591
598
594
114
19
21540
570
590
min. 560
558
Securing the appliance to the
cabinet
A
B
Electrical installation
The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This appliance is supplied with a main
plug and a main cable.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-
F, H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
Total power (W) Section of the ca‐
ble (mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).
ENERGY EFFICIENCY
Product Fiche and information according to EU 65-66/2014
Supplier's name Progress
Progress 21