Operation Manual

TECHNICAL DATA
Voltage 230 V
Frequency 50 Hz
INSTALLATION
Warning! Refer to "Safety information"
chapter.
Building In
570
594
7
590
560
540
20
min. 550
20
590
min. 560
min. 550
min. 560
600
20
A
B
Electrical installation
Warning! Only a qualified person must
do the electrical installation.
The manufacturer is not responsible if
you do not follow the safety precau-
tions from the chapter "Safety Informa-
tion".
This appliance is supplied with a main plug
and a main cable.
Cable
Cable types applicable for installation or re-
placement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the total
power (on the rating plate) and to the table:
Total power Section of the cable
maximum 1380 W 3 x 0.75 mm²
maximum 2300 W 3 x 1 mm²
maximum 3680 W 3 x 1.5 mm²
The hearth cord (green / yellow cable) must
be 2 cm longer than phase and neutral ca-
bles (blue and brown cables).
progress 31