A
5. If you change:
• from natural gas G25 25 mbar to
liquid gas, fully tighten the bypass
screw in.
• from liquid gas to natural gas G25
25 mbar, undo the bypass screw
approximately 1/4 of a turn (1/2 of a
turn for Triple Crown burner).
WARNING! Make sure the
flame does not go out when
you quickly turn the knob from
the maximum position to the
minimum position.
Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable and a plug.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that the
ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up to
a temperature higher than 90° C.
Make sure that you connect the
blue neutral cable to the
terminal with a letter "N" on it.
Connect the brown (or black)
phase cable to the terminal
which has a letter "L". Keep the
phase cable connected at all
times.
Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-FT90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth wire
must be approximately 2 cm longer than
the brown (or black) phase wire.
Assembly
1.
2.
30 Progress