Operation Manual
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A) Removable panel
B) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the
indication and the kitchen unit must be
equipped with vents to let a continuous
supply of air. The electrical connection of
the hob and the oven must be installed
separately for safety reasons and to let easy
remove oven from the unit.
50 cm
2
360 cm
2
180 cm
2
120 cm
2
TECHNICAL INFORMATION
Hob dimensions
Width: 744 mm
Length: 510 mm
Hob recess dimensions
Width: 560 mm
Length: 480 mm
Heat input
Triple Crown
burner:
4.0 kW
Rapid burner: 3.0 kW
Semi-rapid
burner:
2.0 kW
Auxiliary burn-
er:
1.0 kW
TOTAL POW-
ER:
G20/G25 (2E+) 20/25 mbar =
12 kW
G30 (3+) 28-30 mbar = 858
g/h
G31 (3+) 37 mbar = 843 g/h
Electric sup-
ply:
230 V ~ 50 Hz
Category: II2E+3+
Gas connec-
tion:
R 1/2"
Gas supply: G20/G25 (2E+) 20/25 mbar
Appliance
class:
3
By-pass diameters
Burner Ø By-pass in 1/100
mm
Burner Ø By-pass in 1/100
mm
Auxiliary 28 Rapid 42
Semi-rapid 32 Triple Crown 56
Gas burners for NATURAL GAS G20/25 20/25 mbar
BURNER NORMAL POWER kW inj. 1/100 mm
Auxiliary 1.0 70
Semi-rapid 2.0 96
Rapid 3.0 119
Triple Crown 4.0 146
Gas burners for LPG (Butane / Propane)