Specifications
Progress Lighting
Post Office Box 5704
Spartanburg, South Car
olina
29304-5704
www
.progresslighting.com
BR30 and PAR30 Lamp Application Data
Rev. 12/99
Horizontal Surfaces
Clg Ht. Height from floor to ceiling
F.C. Footcandles 30” from floor (work plane)
Dia. & Diameter of effective lighted area and spacing
Spacing to effectively light the horizontal surface
Walls and Vertical Objects
H Height from ceiling to center of beam
D Distance from fixture to wall
F.C. Footcandles at center of beam
L Length of effective lighted area
W Width of effective lighted area
S Spacing of multiple fixtures to effectively light wall
Figure 1
Single lampholder
D
H
FC
L
W
Figure 2
Multiple lampholders
D
H
FC
L
S
CBCP - Center Beam Candlepower
*L is height of wall
H F.C. L W S F.C. L W S F.C. L W S F.C.
Clg.
Ht.
Dia. &
Spacing
Walls and Vertical Objects
Horizontal Surfaces
65BR30FL 2 46 5.7 2.9 2.3 34 5.1 3.8 2.9 23 5.6 4.7 3.6 8 17 5.1
CBCP - 525 3 22 17.3 3.8 2.9 21 8.6 4.4 3.4 17 12.0 5.2 4.0 9 12 6
Beam - 55 deg. 4 12 * 4.7 3.6 13 16.7 5.2 4.0 11 11.4 5.9 4.5 10 9 6.9
D = 2 FT D = 3 FT D = 4 FT
BR30 Flood Lamp
65BR30SP 3 69 2.5 1.3 1.2 64 2.2 1.5 1.4 52 2.2 1.8 1.7 8 54 1.9
CBCP - 1625 4 36 4.0 1.6 1.5 39 3.1 1.8 1.7 36 2.9 2.0 1.9 9 38 2.3
Beam - 20 deg. 5 21 6.3 1.9 1.8 25 4.4 2.1 2.0 25 3.8 2.3 2.2 10 29 2.6
D = 2 FT D = 3 FT D = 4 FT
BR30 Spot Lamp
50PAR30/HIR/FL 3 64 5.3 2.3 2.0 59 4.2 2.7 2.4 48 4.2 3.2 2.8 8 50 3.3
CBCP - 1500 4 34 10.4 2.8 2.5 36 6.4 3.2 2.8 33 5.6 3.6 3.1 9 36 3.9
Beam - 35 deg. 5 19 24.2 3.4 3.0 23 9.9 3.7 3.2 23 7.6 4.0 3.6 10 27 4.5
50PAR30FL 3 60 5.3 2.3 2.0 55 4.2 2.7 2.4 45 4.2 3.2 2.8 8 46 3.3
CBCP - 1400 4 31 10.4 2.8 2.5 34 6.4 3.2 2.8 31 5.6 3.6 3.1 9 33 3.9
Beam - 35 deg. 5 18 24.2 3.4 3.0 21 9.9 3.7 3.2 21 7.6 4.0 3.6 10 25 4.5
75PAR30FL 3 85 5.8 2.4 2.1 79 4.5 2.8 2.5 64 4.5 3.3 2.9 8 66 3.5
CBCP - 2000 4 45 12.1 3.0 2.6 48 6.9 3.3 2.9 44 6.0 3.8 3.3 9 47 4.1
Beam - 35 deg. 5 26 32.3 3.6 3.1 30 11.0 3.9 3.4 31 8.3 4.3 3.7 10 36 4.8
75PAR30FL-L 3 133 3.2 1.6 1.5 122 2.8 1.9 1.8 90 2.9 2.2 2.1 8 102 2.4
CBCP - 3100 4 70 5.5 2.0 1.9 74 4.0 2.2 2.1 68 3.7 2.5 2.3 9 74 2.8
Beam - 25 deg. 5 40 9.3 2.4 2.2 47 5.8 2.6 2.4 40 4.9 2.8 2.7 10 55 3.2
D = 2 FT D = 3 FT D = 4 FT
PAR30
Flood Lamps
50PAR30/HIR/NSP 4 313 1.3 0.8 0.8 287 1.3 0.9 0.9 247 1.3 1.0 1.0 12 144 1.5
CBCP - 13,000 6 130 2.4 1.1 1.0 139 2.1 1.1 1.1 154 1.8 1.2 1.2 16 71 2.1
Beam - 9 deg. 8 63 4.0 1.3 1.3 73 3.2 1.4 1.4 77 2.8 1.5 1.5 20 42 2.7
50PAR20NSP 4 166 1.5 0.9 0.9 152 1.4 1.0 1.0 131 1.4 1.1 1.1 10 123 1.3
CBCP - 6,900 6 69 2.7 1.2 1.2 74 2.3 1.3 1.2 81 2.0 1.3 1.3 12 76 1.7
Beam - 10 deg. 8 33 4.5 1.5 1.5 39 3.6 1.6 1.5 41 3.2 1.7 1.6 14 52 2.0
75PAR30NSP 4 313 1.5 0.9 0.9 287 1.4 1.0 1.0 247 1.4 1.1 1.1 10 231 1.3
CBCP - 13,000 6 130 2.7 1.2 1.2 139 2.3 1.3 1.2 154 2.0 1.3 1.3 14 98 2.0
Beam - 10 deg. 8 63 4.5 1.5 1.5 73 3.6 1.6 1.5 77 3.2 1.7 1.6 18 54 2.7
75PAR30NSP-L 4 217 1.5 0.9 0.9 199 1.4 1.0 1.0 171 1.4 1.1 1.1 10 160 1.3
CBCP - 9,000 6 90 2.7 1.2 1.2 96 2.3 1.3 1.2 107 2.0 1.3 1.3 14 68 2.0
Beam - 10 deg. 8 44 4.5 1.5 1.5 51 3.6 1.6 1.5 53.3 3.2 1.7 1.6 18 37 2.7
D = 3 FT D = 4 FT D = 5 FT
PAR30
Spot Lamps
H F.C. L W S F.C. L W S F.C. L W S F.C.
Clg.
Ht.
Dia. &
Spacing
Walls and Vertical Objects
Horizontal Surfaces
H F.C. L W S F.C. L W S F.C. L W S F.C.
Clg.
Ht.
Dia. &
Spacing
Walls and Vertical Objects
Horizontal Surfaces
H F.C. L W S F.C. L W S F.C. L W S F.C.
Clg.
Ht.
Dia. &
Spacing
Walls and Vertical Objects
Horizontal Surfaces