Installation & Assembly
WIRENUTS
FIXTURE WIRE
UL LISTED
WHITE OR IDENTIFIED
BARE, OR GREEN
PLAIN OR BLACK
FIXTURE WIRE
FIXTURE GROUND
WHITE SUPPLY
BLACK SUPPLY
FROM SUPPLY
GROUND WIRE
BARE, OR GREEN
WIRE
WIRE
WIRE
ALAMBRE DEL
SUMINSTRO BLANCO
ALAMBRE DEL
SUMINSTRO NEGRO
ALAMBRE DE TIERRA
VERDE O NEUTRO
DEL SUMINISTRO
O NEUTRO
CONECTADOR
DE LA LAMPARA
ALAMBRE BLANCO
O IDENTIFICADO
UL CALIFICADO
ALAMBRE NEGRO
DE LA LAMPARA
VERDE O NEUTRO
ALAMBRE DE TIERRA
DE LA LAMPARA
RELAIS UL QUALIFIE
COINCEUR DE
BLANC OU IDENTIFIABLE
FILS DE CONNECTEUR
NOIR OU
FILS DE CONNECTEUR
OU NEUTRE
SANS MARQUES
FILS VERT
BLANC
NOIR
FILS VERT
DU COURANT
OU NEUTRE
FILS DE COURANT
FILS DE COURANT
FIG.1
FIG.3
FIG.4
FIG.5
FIG.2
"A"
"A"
FIG.7
FIG.6
"A-A"
8
7
6
13
15
16
19
16
17
15
3
2
5
24
14
6
15
16
21
18
26
18
21
26
WARNING:
Use only those trims, lamps, and maximum wattages proper for this fixture, as indicated on the
label within the housing (3) (Fig. 2).
WARNING: National Electrical Code, Article 110-
3 (b), states that “Listed or labeled equipment shall be used
or
installed in accordance with any instructions included in the listing or labeling”. Use only Prescolite UL listed
trims. Use of other trims not listed in this fixture, including those that are UL classified, is a violation of N.E.C.
110-3 (b) and voids all warranties.
WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects,
and/or other reproductive harm. Thoroughly wash your hands after installing, handling, cleaning, or otherwise
touching this product.
WARNING: If any special control devices are used with this fixture, follow the instructions carefully to assure
full compliance with N.E.C. requirements. If there are any questions, contact a qualified electrical contractor.
1. For Wooden Joists: Extend the Bar Hangers (6), use joist alignment tabs to locate fixture and position
underneath the support joist (8). Drive the 4 Nails (7) into Joists (8) (Fig. 1 & 3). Drive additional nails through
holes in Bar Hanger for alternate support if required. Bar Hangers may be bent to fix tight mounting conditions.
2. For Suspended Ceilings: Place the Fixture on the ceiling grid with the "T" Bars (9) running through the Bar
Hanger Notches (10). Using a flat head screwdriver or other tool, bend the integral t-bar mounting tabs (11)
downward to a vertical position (Fig. 4). Secure housing to the support structure with tie wire (supplied by
others) in the holes supplied. Sheetmetal screws (supplied by others) can also be used in the holes supplied
(20).
3. Locate Housing (3)
along Bar Hanger in desired position and, using pliers, squeeze the 4 Locking Tabs (12)
on the Plaster Frame (13) tightly over the Bar Hangers to prevent further Housing movement.
4. As desired, hanger bars (6) may be shortened at score mark to fit tight mounting conditions and joist
alignment tabs removed to adjust vertically as needed by breaking off with pliers.
5. Unsnap Junction Box Cover (14) by lifting the Leaf Spring (24).
6. Run supply wires through UL Listed connectors (not supplied) in one
of the five Pryouts (15) on the Junction
Box (16) or Type NM cable (ROMEX) through an Opening above the Wire Retaining Plate (17). Connect
Supply Wires (19) as shown in Fig 5 & 7. Replace Cover.
7. Adjust position of socket (21) by loosening thumbscrew (26) and rotating bracket socket (18). Retighten
thumbscrew (Fig. 2 & 6).
8. ONLY install Progress Trim P8004 (PURCHASED SEPARATELY) according to Instructions supplied with
these trims. Use only lamp types approved for these Trims. DO NOT EXCEED MAXIMUM LISTED
WATTAGES.
9. To gain access to junction box (16) after ceiling is finished, remove screw (2) and access door (5) inside of
fixture. Junction box cover plate (14) can now be removed for service.
INSTRUCTION SHEET MUST BE REMOVED FROM FIXTURE
PRIOR TO ENERGIZING.
THIS UNIT IS TO BE USED ONLY IN CEILINGS WITH 0-12 TO 12-12 PITCH.
THIS UNIT IS ONLY TO BE MOUNTED WITH JUNCTION BOX SLOPED UP.
(AS SHOWN IN FIG. 2)
Assembly & Installation Instructions
Read instructions carefully and turn electricity off at main
circuit breaker panel before beginning installation.
CAUTION:
PAGE ofPAGE of
P645-TG / P645-AT
1 44 4
SPEC. NO. 023942 Rev. C (10-08-12)
12
13
10
11
7
20
9
Ceiling Opening is to be 67/8" in Diameter
6
6
SPEC. NO. 023942 Rev. C (10-08-12)