Installation Guide

Instructions For Self-Diagnostic Test:
Once the unit is properly installed according to the installation instruction sheet and AC power supplied, the dual color LED indicator
will come ON and the self-diagnostic test function will automatically initiate. The LED indicates the unit’s status. A STEADY GREEN
LED indicates normal service; FLASHING GREEN indicates the unit is testing; GREEN/RED FLASHING indicates the battery is charging;
RED (in different combinations) would indicate a service alert. Refer to he SERVICE INDICATION chart below for more details. The LED
would be OFF when the unit is in emergency mode.
Self-Diagnostic Service
The self-diagnostic function is factory preset and performs the following:
a. Monitoring of battery, battery charger, and lamps.
b. Self-testing and a 30-second or longer discharge once every 30 days, after AC power has been supplied for a minimum of 24 hrs.
c. Self-testing and a 30-minute or longer discharge once every 180 days, after AC power has been supplied for a minimum of 24 hrs.
d. Self-testing and a 90-minute discharge once every 365 days, after AC power has been supplied for a minimum of 24 hrs.
Service Indication
LED
Indicator
Status
One
Flash Red
Replace
Electronics
Two
Flash Red
Replace
Battery
Four
Flash Red
Replace
lamp head board
Steady
Red
Battery
Disconnected
Solid
Green
Trickle
Charge
Flashing
Green
In
Test
Red/Green
Flashing
High
Charge
Action
Reaction
& LED Indication
Push
test button Once (within 2 seconds)
30
-second test: Flashing Green
Push
test button Twice (within 2 seconds)
30
-minute test: Green Flashing twice
Push
test button Three times (within 2 seconds)
90
-minute test: Green Flashing thre times
Push
test button and hold for 3 seconds (In test mode)
Cancels
test. If self-test is cancelled it is recommended that a
manual
test of the same duration be performed at a more
convenient time to ensure compliance
Push
test button and hold for 6 seconds (In test mode)
System
reset
Manual Testing
The unit also provides for manual testing by pushing the test button in a specific pattern.
Warning:
a) Make sure that power is OFF before making any electrical connections.
b) Unused wires must be capped using enclosed wire nuts.