Specification Sheet

Photometrics:
P Medium LED Flex Track Head
Track mounted • Dry location listed
PK
ELECTRICAL DATA P--K
Input Voltage  V
Input Frequency  Hz
Input Current . A
Input Power .
Power Factor >.
THD <%
EMI Filtering FCC Title , Part  Class B
Operating Temperature - °C to º C
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 17.01924 PAGE: 4 OF 8
ISSUE DATE: 07/13/17
PREPARED FOR: PROGRESS
CATALOG NUMBER: P90210927K9
DEG CANDELA LUMENS
0 1262
5 1193 101
15 416 122
25 188 89
35 150 86
45 13 19
55 3 3
65 0 0
75 0 0
85 0 0
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 313 74.3
0- 40 399 94.8
0- 60 420 99.9
0- 90 420 100.0
90-180 0 0.0
0-180 420 100.0
EFFICACY = 61.3 lm/W
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 0.41
PLANE : 0-DEG 90-DEG
SHIELDING ANGLES : 90 90
LUMINOUS DIAMETER: 2.500
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE
IN DEG
45 5805.
55 1652.
65 0.
75 0.
85 0.
450
900
1350
15˚ 30˚
45˚
60˚
75˚
90˚
P--K
LED Light Engine:  K + CRI
System Wattage: .
Fixture delivered lumens: 
Fixture Efficacy: .
Spacing Criteria: .
ZONAL LUMEN SUMMARY
Zone Lumens %Fixt
0-30 313 74.3
0-40 399 94.8
0-60 420 99.9
0-90 420 100.0
90-180 0 0.0
0-180 420 100.0
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
 
 
  
  
  
  
 
 
  
 
 