(P8241-20/30K9-AC1-L06) Specification Sheet

P8241 Series
LED New Construction and Remodel • Wet Location
Photometrics:
P8241-28/30K9-AC1-L06
ELECTRICAL DATA P8241-28/30K9-AC1-L06
Input Voltage 120V
Input Frequency 60 Hz
Input Current 700mA
Power Factor >0.90
THD <20%
EMI Filtering FCC 47CFR
Part 15, Class B
Operating Temperature -30ºC to 30ºC
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
Ceiling to Floor
Nadir Height (ft)
FC FC Dia (ft) FC Dia (ft) FC Dia (ft) Fixture Spacing (ft) RCR 2 RCR 5 RCR 7
23 22 1 18 3 12 4 6 4.0
9 927456 8 7.0
4 433629 10.5 10.0
3 332 7 2 11 12 11.0
Single Unit, Initial Footcandles, 30" Work Plane
3
5
37
45
Multiple Units, Initial Footcandles, 30" Work Plane
10
o
20
o
2126
11
30
o
15
7
Spacing is Maximum Over Work Plane, SMH= 1.2
9
4
PERFORMANCE DATACHART
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
NVLAP LAB CODE: 201003-0
®
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
REPORT NUMBER: 8,140 PAGE: 1 OF 4
ISSUE DATE: 7/17/2015 4:18:57 PM
PREPARED FOR: PRESCOLITE
HLI TEST 15.01334
LUMINAIRE: LBSQ5LEDA6L30K9 WH
24.9 deg C
0.9309
39.20%
0.09302
120.09
41:33.8 Stable
0.10 %
0.47 %
0.00800
0.00112
999.0000 - -9,990.0000
680.42
DEG CANDELA LUMENS
0.0
0 276
5 275 26
15 262 74
25 238 110
35 202 126
45 159 123
55 115 103
65 73 72
75 36 38
85 6 8
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 210 30.8
0- 40 336 49.4
0- 60 561 82.6
0- 90 679 100.0
90-180 0 0.0
0-180 679 100.0
EFFICACY = 65.4 Lm/W
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 1.2
100
200
300
15˚ 30˚
45˚
60˚
75˚
90˚
100
200
300
0º 15º 30º
45º
60º
75º
90º
Test No. 15.01268 70040774
Tested at 25ºC Ambient in accordance to IESNA LM-79-2008
P8241-28/30K9-AC1-L06
LED Light Engine: 3000K, 91 CRI
System Wattage: 10.4W
Fixture Delivered Lumens: 680
Fixture Efficacy: 65.4
Spacing Criteria: 1.2
CANDELA
DISTRIBUTION
DEG CANDELA
0 276
5 275
15 262
25 238
35 202
45 159
55 115
65 73
75 36
85 6
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXTURE
0-30 210 30.8
0-40 336 49.4
0-60 561 82.6
0-90 679 100.0
COEFFICIENTS OF UTILIZATION
Room Cavity
Ratio
% Effective Ceiling Cavity Reectance
80% 70% 50% 30%
20% Effective Floor Cavity Reectance
% Wall Reectance
70 50 30 10 70 10 50 30 50 30
1 109 105 101 97 107 96 99 96 95 92
3 92 81 74 67 89 67 77 71 74 69
5 78 65 56 50 76 50 62 55 60 54
7 67 54 45 39 65 39 51 44 50 43
9 58 45 37 32 57 32 43 36 42 36
10 55 42 34 29 53 29 40 33 39
33
P8241-28/30K9-AC1-L06
Test No. 15.01268
70040774