Specification Sheet

LED 8" Pro-Optic
®
LED Retrofit Downlight Recessed
P8102/P8121/P8133
Test conducted under stabilized laboratory conditions following published industry standards. Various operating factors can cause differences
between laboratory data and actual field measurements.
REPORT NUMBER: 3795 PAGE: 1 OF 4
ISSUE DATE: 12/28/10
PREPARED FOR: Prescolite
CATALOG NUMBER: RLF8LED 8LFLED5735K
LUMINAIRE: 8" LiteFrame w/ 3002 Alloy Aluminum - Specular finish
LAMP CAT. NO.: LED DLM 2000 35W/835 UL
LAMP: Philips Fortimo LED @ 34W / 2000 Lumens
BALLAST CAT. NO.: 913701213402
BALLAST: Philips Electronic Driver
ELECTRICAL: 24.6C, 120.0v, 32.9w, 0.276A
MOUNTING: Recessed
NOTE: DATA SHOWN IS ABSOLUTE FOR THE
SAMPLE PROVIDED.
DEG CANDELA LUMENS
0 981
5 1005 97
15 1072 305
25 1146 530
35 975 586
45 95 124
55 7 7
65 1 1
75 0 0
85 0 0
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 932 56.5
0- 40 1518 92.0
0- 60 1649 99.9
0- 90 1650 100.0
90-180 0 0.0
0-180 1650 100.0
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 1.2
LUMINOUS DIAMETER: 7.750
LUMINANCE DATA IN CANDELA/SQ METER
ANGLE AVERAGE
IN DEG
45 4413.
55 401.
65 78.
75 0.
85 0.
Approved
Checked
350
700
1050
15˚ 30˚
45˚
60˚
75˚
90˚
LUMINANCE DATA IN CANDELA/
SQ. METER
Angle in Vertical Average - 0º
45° 15105
55° 312
65° 141
75° 0
85° 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %LUMINAIRE
0-30 501 56.0
0-40 820 91.7
0-60 894 99.9
0-90 895 100.0
90-180 0 0.0
0-180 865 100.0
P8102-EB WITH P8121-21A/35K
LED Light Engine: 3500K, 80 CRI
System Wattage: 18.5W
Fixture Delivered Lumens: 916
Fixture Efficacy: 50
Spacing Criteria: 1.2
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
0 529
5 542 52
15 571 163
25 619 286
35 529 319
45 62 71
55 4 4
65 1 0
75 0 0
85 0 0
90 0
Test No. 3815
Tested at 25ºC Ambient in accordance to IESNA LM-79-2008
% Effective Floor Cavity Reflectance
80% 70% 50% 30% 10%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
1 113 110 107 105 111 108 106 103 104 102 100 100 99 97 97 96 94
2 107 102 97 94 105 100 96 91 97 93 91 94 91 89 91 89 87
3 101 94 89 84 99 92 88 82 90 86 82 87 84 81 85 82 80
4 95 87 81 76 93 86 80 75 83 79 75 81 77 74 79 76 73
5 89 80 74 69 88 79 73 68 77 72 68 76 71 68 74 70 67
6 84 74 68 63 83 74 67 62 72 67 62 71 66 62 69 65 62
7 79 69 62 58 78 68 62 57 67 61 57 66 61 57 65 60 57
8 75 64 58 53 73 64 57 53 63 57 53 61 56 53 60 56 52
9 71 60 53 49 69 59 53 49 58 53 49 57 52 49 57 52 48
10 67 56 50 45 66 55 49 45 55 49 45 54 49 45 53 48 45
Room Cavity
Ratio
COEFFICIENTS OF UTILIZATION Zonal Cavity Method
REPORT NUMBER: 3517 PAGE: 1 OF 4
ISSUE DATE: 08/25/10
PREPARED FOR: PRESCOLITE
CATALOG NUMBER: RLF8LED
LUMINAIRE: 8" LiteFrame w/ 3002 Alloy Aluminum Specular Finish Reflector
LAMP CAT. NO.: 1100 18W835UL
LAMP: LED DLM - FORTIMO
BALLAST CAT. NO.: 913701213402
BALLAST: 1 - LED ELECTRONIC DRIVER - PHILIPS
Tested under stabilized laboratory
conditions. Various operating
factors can cause differences
between laboratory data and actual
field measurements. 25.3C, 120.1V,
.154A, 18.23W - LED-46.2C
MOUNTING: RECESSED
SAME TEST SETUP AS 3483 WITH PHOTOMETER
HEAD ZEROED.
NOTE: DATA SHOWN IS ABSOLUTE FOR THE
SAMPLE PROVIDED.
DEG CANDELA LUMENS
0 529
5 542 52
15 571 163
25 619 286
35 529 319
45 62 71
55 4 4
65 1 0
75 0 0
85 0 0
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 501 56.0
0- 40 820 91.7
0- 60 894 99.9
0- 90 895 100.0
90-180 0 0.0
0-180 895 100.0
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 1.2
Approved
Checked
190
380
570
15˚ 30˚
45˚
60˚
75˚
90˚
190
380
570
0º 15º 30º
45º
60º
75º
90º
LUMINANCE DATA IN CANDELA/
SQ. METER
Angle in Vertical Average - 0º
45° 4413
55° 401
65° 78
75° 0
85° 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %LUMINAIRE
0-30 932 56.5
0-40 1518 92.0
0-60 1649 99.9
0-90 1650 100.0
90-180 0 0.0
0-180 1650 100.0
P8102-EB WITH P8133-21A/35K
LED Light Engine: 3500K, 80 CRI
System Wattage: 32.9W
Fixture Delivered Lumens: 1650
Fixture Efficacy: 50 lm/watt
Spacing Criteria: 1.2
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
0 981
5 1005 97
15 1072 305
25 1146 530
35 975 586
45 95 124
55 7 7
65 1 1
75 0 0
85 0 0
90 0
Test No. 3971
Tested at 25ºC Ambient in accordance to IESNA LM-79-2008
% Effective Floor Cavity Reflectance
80% 70% 50% 30% 10%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
1 113 110 108 105 111 108 106 103 104 102 100 100 99 97 97 96 94
2 107 102 97 94 105 100 96 93 97 93 91 94 91 89 91 89 87
3 101 94 89 84 99 93 88 84 90 86 82 87 84 81 85 82 80
4 95 87 81 76 93 86 80 76 84 79 75 81 77 74 80 76 73
5 90 80 74 69 88 79 74 69 78 72 68 76 71 68 74 70 67
6 84 75 68 63 83 74 68 63 72 67 63 71 66 62 69 65 62
7 79 69 63 58 78 69 62 58 67 62 58 66 61 57 65 60 57
8 75 64 58 53 74 64 58 53 63 57 53 62 57 53 61 56 53
9 71 60 54 49 70 60 53 49 59 53 49 58 52 49 57 52 49
10 67 56 50 46 66 55 50 45 55 49 45 54 49 45 53 48 45
Room Cavity
Ratio
COEFFICIENTS OF UTILIZATION Zonal Cavity Method
350
700
1050
0º 15º 30º
45º
60º
75º
90º
Page 3 of 3