Specification Sheet

LED 4” Pro-Optic
®
LED Recessed
New Construction Downlight
P8064/P8067/P8206
Page 3 of 3
Test conducted under stabilized laboratory conditions following published industry standards. Various operating factors can cause differences
between laboratory data and actual field measurements.
REPORT NUMBER: 4149 PAGE: 1 OF 4
ISSUE DATE: 05/17/11
PREPARED FOR: PRESCOLITE
CATALOG NUMBER: LF4LED 4LFLED735K
LUMINAIRE: 6" LED DOWNLIGHT
LAMP CAT. NO.: LED DLM2000 34W/835 UL
LAMP: Philips Fortimo LED DLM
BALLAST CAT. NO.: 913701213402
BALLAST: Philips LED Electronic Driver
ELECTRICALS: 24.5 C, 120.0 V, 32.8 W,
0.275 A
MOUNTING: RECESSED
NOTE: DATA SHOWN IS ABSOLUTE FOR THE
SAMPLE PROVIDED.
DEG CANDELA LUMENS
0 1170
5 1242 120
15 1322 375
25 1208 552
35 766 472
45 172 141
55 9 10
65 3 2
75 1 1
85 1 0
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 1047 62.6
0- 40 1519 90.8
0- 60 1670 99.8
0- 90 1673 100.0
90-180 0 0.0
0-180 1673 100.0
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 1.1
LUMINOUS DIAMETER: 6.000
LUMINANCE DATA IN CANDELA/SQ METER
ANGLE AVERAGE
IN DEG
45 13330.
55 860.
65 389.
75 212.
85 629.
Approved
Checked
450
900
1350
15˚ 30˚
45˚
60˚
75˚
90˚
Test conducted under stabilized laboratory conditions following published industry standards. Various operating factors can cause differences
between laboratory data and actual field measurements.
REPORT NUMBER: 3739 PAGE: 1 OF 4
ISSUE DATE: 11/29/10
PREPARED FOR: Prescolite, Inc
CATALOG NUMBER: LF4LED 4LFLED535K
LUMINAIRE: Reflector PN 93033107 REV P1 specular finish. LED is slightly
off-center. Heat sink is standard product produced by Nuventix -
120mm without fan - Synjet.
LAMP CAT. NO.: LED DLM1100 19W/835 UL
LAMP: Fortimo LED DLM
BALLAST CAT. NO.: 913701213402
BALLAST: Philips Electronic driver
ELECTRICAL: 24.8C, 120.1v, 0.155A, 18.4w
MOUNTING: Recessed
NOTE: DATA SHOWN IS ABSOLUTE FOR THE
SAMPLE PROVIDED.
DEG CANDELA LUMENS
0 603
5 620 60
15 673 191
25 627 287
35 412 253
45 94 78
55 5 6
65 2 1
75 0 0
85 0 0
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 538 61.3
0- 40 791 90.2
0- 60 875 99.8
0- 90 877 100.0
90-180 0 0.0
0-180 877 100.0
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 1.1
LUMINOUS DIAMETER: 4.000
LUMINANCE DATA IN CANDELA/SQ METER
ANGLE AVERAGE
IN DEG
45 16391.
55 1075.
65 584.
75 0.
85 0.
Approved
Checked
250
500
750
15˚ 30˚
45˚
60˚
7
9
LUMINANCE DATA IN CANDELA/
SQ. METER
Angle in Vertical Average - 0º
45° 16391
55° 1075
65° 584
75° 0
85° 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %LUMINAIRE
0-30 538 61.3
0-40 791 90.2
0-60 875 99.8
0-90 877 100.0
90-180 0 0.0
0-180 877 100.0
P8064-EB P8067-21A/35K
LED Light Engine: 3500K, 80 CRI
System Wattage: 17.3W
Fixture Delivered Lumens: 877
Fixture Efficacy: 51
Spacing Criteria: 1.2
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
0 603
5 620 60
15 673 191
25 627 287
35 412 253
45 94 78
55 5 6
65 2 1
75 0 0
85 0 0
90 0
Test No. 3739
Tested at 25ºC Ambient in accordance to IESNA LM-79-2008
250
500
750
0º 15º 30º
45º
60º
75º
90º
LUMINANCE DATA IN CANDELA/
SQ. METER
Angle in Vertical Average - 0º
45° 13330
55° 860
65° 389
75° 212
85° 629
ZONAL LUMEN SUMMARY
ZONE LUMENS %LUMINAIRE
0-30 1047 62.6
0-40 1519 90.8
0-60 1670 99.8
0-90 1673 100.0
90-180 0 0.0
0-180 1673 100.0
P8064-EB P8206-21A/35K
LED Light Engine: 3500K, 80 CRI
System Wattage: 32.9W
Fixture Delivered Lumens: 1673
Fixture Efficacy: 50
Spacing Criteria: 1.1
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
0 1170
5 1242 120
15 1322 375
25 1208 552
35 766 472
45 172 141
55 9 10
65 3 2
75 1 1
85 1 0
90 0
Test No. 4149
Tested at 25ºC Ambient in accordance to IESNA LM-79-2008
450
900
1350
0º 15º 30º
45º
60º
75º
90º
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method
Room Cavity
Ratio
% Effective Ceiling Cavity Reectance
80% 70% 50% 30% 10%
20% Effective Floor Cavity Reectance
% Wall Reectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
1 113 110 108 105 111 108 106 104 104 102 101 100 99 98 97 96 95
2 107 102 98 94 105 100 96 93 97 94 91 94 91 89 91 89 87
3 101 94 89 85 99 93 88 84 90 86 83 88 85 82 86 83 80
4 96 88 82 77 94 86 81 77 84 80 76 82 78 75 80 77 74
5 90 81 75 71 89 80 75 70 79 73 70 77 72 69 75 71 68
6 85 76 69 65 84 75 69 64 73 68 64 72 67 64 71 66 63
7 80 71 64 60 79 70 64 59 69 63 59 67 62 59 66 62 58
8 76 66 59 55 75 65 59 55 64 59 55 63 58 54 62 58 54
9 72 62 55 51 71 61 55 51 60 55 51 59 54 51 58 54 50
10 68 58 52 47 67 57 51 47 56 51 47 56 51 47 55 50 47
P8064-EB P8067-21A/35K
Test No. 3739
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method
Room Cavity
Ratio
% Effective Ceiling Cavity Reectance
80% 70% 50% 30% 10%
20% Effective Floor Cavity Reectance
% Wall Reectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
1 113 110 108 105 111 108 106 104 104 102 101 100 99 98 97 96 95
2 107 102 98 94 105 100 97 93 97 94 91 94 92 89 91 89 87
3 101 95 89 85 99 93 88 85 91 87 83 88 85 82 86 83 81
4 96 88 82 78 94 87 81 77 85 80 76 82 78 75 81 77 74
5 91 82 75 71 89 81 75 71 79 74 70 77 73 69 76 72 69
6 86 76 70 65 84 75 69 65 74 68 64 72 68 64 71 67 64
7 81 71 65 60 79 70 64 60 69 64 60 68 63 59 67 62 59
8 76 66 60 56 75 66 60 55 65 59 55 64 59 55 63 63 55
9 72 62 56 52 71 62 56 51 61 55 51 60 55 51 59 59 51
10 69 58 52 48 68 58 52 48 57 52 48 56 51 48 55 55 47
P8064-EB P8206-21A/35K
Test No. 4149v