(P8066-09) Specification Sheet
P87-AT WITH P8066-31
Report No. 98097
No. Lamps: 1 Type Lamp: 75PAR30 SN - GE Total Lumens: 1100
Fixture Efficiency: 91.4%
S/MH Ratio: 0.5
Single Fixture Data
Ceiling
Ht.(Ft.)
10% Values
Ft.-C Beam Dia.
Zero
Degrees
Ft.-C
50% Values
Ft.-C Beam Dia.
Ft.-C (Footcandles) are initial and measured 2'-6" from floor
16  1.4  13 13.9  6.9  8
14  1.9  11 19.1  9.6  7
12  2.8  9 28.0  14.0  6
10  4.5  7 45.0  22.5  4
8  8.4  5 83.6  41.8  3
Beam Angle - 53 Beam Angle - 33
Quick Calculator Charts
0 100 200 300 400 500
0
8
16
24
32
40
Initial Footcandles
2'6" from floor
Area per Fixture (sq. ft.)
Room Reflectances: 80% Ceiling, 50% Wall, 20% Floor
Ceiling Ht.= 9 ft.
Medium Room - RCR=5.0
120 to 200 square foot area
0 100 200 300 400 500
0
10
20
30
40
50
Initial Footcandles
2'6" from floor
Area per Fixture (sq. ft.)
Room Reflectances: 80% Ceiling, 50% Wall, 20% Floor
Ceiling Ht.= 10 ft.
Large Room - RCR=2.0
1500 to 2500 square foot area
5
15
25
35
45
55
65
75
85
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
DISTRIBUTION CURVE INTENSITY DATA
2529
2487
2203
1613
919
425
234
144
86
36
10
5
2
1
0
0
0
0
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
80 70 50 30 10 0
RW
RC
10
9
8
7
6
5
4
3
2
1
0
Effective Floor Cavity Reflectance 0.20
ZONAL CAVITY COEFFICIENTS OF UTILIZATION
109 109 109 109 106 106 106 106 102 102 102  97 97  97 93  93 93  91
105 103 101  99 103 101  99 97  97 96  94 94  93 92  90 90  89 87
101  97 94  91 99  95 93  90 93  90 88  90 88  86 87  86 85  83
 97 92  88 85  95 91  87 85  88 86  83 86  84 82  84 82  81 79
 93 87  83 80  92 86  83 80  85 81  79 83  80 78  81 79  77 76
 90 83  79 76  88 83  79 76  81 78  75 80  77 74  78 76  74 73
 86 80  75 72  85 79  75 72  78 74  72 77  73 71  76 73  71 70
 83 76  72 69  82 76  72 69  75 71  68 74  71 68  73 70  68 67
 80 73  69 66  79 73  69 66  72 68  66 71  68 65  70 67  65 64
 78 71  66 63  77 70  66 63  69 66  63 69  65 63  68 65  63 62
 75 68  64 61  74 68  64 61  67 63  61 66  63 60  66 63  60 59