P SERIES
IN LED New Construction and Remodel • Wet location listed
PK
Photometrics:
ELECTRICAL DATA P8061-28-30K
Input Voltage 120 V
Input Frequency 60 Hz
Input Current 0.08 A
Power Factor >0.90
THD <20%
EMI Filtering FCC 47CFR
Part 15, Class B
Operating Temperature -30 °C to 30 °C
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
P8061-28-30K
LED Light Engine: K, CRI
System Wattage:
Fixture Delivered Lumens:
Fixture Efficacy:
Spacing Criteria: .
ZONAL LUMEN SUMMARY
Zone Zone Lumens Total Lumens % Luminaire
0-10 38.76 38.76 5.99
10-20 103.4 142.2 22
20-30 140.6 282.7 43.7
30-40 149.2 431.9 66.8
40-50 125.5 557.5 86.2
50-60 68.88 626.3 96.8
60-70 18.39 644.7 99.7
70-80 1.618 646.3 99.9
80-90 0.3587 646.7 100