Specification
Photometrics:
5in LED Outdoor Up/Down Cylinder
Wall mounted • Damp location listed
P/K
ELECTRICAL DATA P-/K
Input Voltage V
Input Frequency Hz
Input Current
Input Power
Power Factor .
THD <%
FCC FCC Title , Part Class B
Operating Temperature - °C to °C
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
701 Millenium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
REPORT NUMBER: 17.02768 PAGE: 3 OF 9
ISSUE DATE: 10/20/17
PREPARED FOR: PROGRESS
CATALOG NUMBER: P5675-3130K
LUMINAIRE: 5" 17W LED Direct/Indirect Cylinder
LAMP: 2- 3000K LED Modules
MOUNTING: Wall
DEG CANDELA LUMENS
0 446
5 450 43
15 416 115
25 272 123
35 104 65
45 2 8
55 1 0
65 0 0
75 0 0
85 0 0
90 0
95 0 0
105 1 0
115 2 2
125 17 18
135 83 64
145 167 104
155 282 130
165 413 114
175 452 43
180 454
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 280 33.8
0- 40 346 41.7
0- 60 354 42.7
0- 90 354 42.7
90-120 3 0.3
90-130 21 2.5
90-150 189 22.8
90-180 476 57.3
0-180 830 100.0
TOTAL INPUT WATTS = 33.9
EFFICACY = 24.5 Lm/W
CIE TYPE - DIRECT-INDIRECT
LUMINAIRE SPACING CRITERION = 0.8
220
440
220
440
0˚ 15˚ 30˚ 45˚
60˚
75˚
90˚
180˚ 165˚ 150˚ 135˚
120˚
105˚
90˚
P-/K
LED Light Engine: K CRI CRI
System Wattage:
Fixture delivered lumens:
Fixture Efficacy: .
Spacing Criteria: .
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-30 280 33.8
0-40 346 41.7
0-60 354 42.7
0-90 354 42.7
90-120 3 0.3
90-130 21 2.5
90-150 189 22.8
90-180 476 57.3
0-180 830 100.0
CANDELA DISTRIBUTION
DEG CANDELA LUMENS