Specification

P5675-30/30K
Photometrics:
ELECTRICAL DATA P5675-30/30K
Input Voltage  V
Input Frequency  Hz
THD <%
EMI/RFI FCC Title , Part , Class B
Operating Temperature - °C to  °C
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
NVLAP LAB CODE: 201003-0
®
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
REPORT NUMBER: 16.00018.1 PAGE: 3 OF 9
ISSUE DATE: 01/06/16
PREPARED FOR: PROGRESS
CATALOG NUMBER: P5675-3030K9
LUMINAIRE: 5" diameter up/down wall mount LED cylinder with LEDs moved
closer to opening.Type V
LAMP CAT. NO.: 93047261-4030
LAMP: 40- Nichia 3000K LEDs
REFRACTOR: Sabic polycarbonate LUX7430C-NAT, Lens 93047259-3
MOUNTING: Pendant
NOTE: DATA SHOWN IS ABSOLUTE FOR THE
SAMPLE PROVIDED.
DEG CANDELA LUMENS
0 453
5 454 43
15 439 122
25 343 157
35 243 152
45 166 128
55 99 89
65 60 59
75 31 33
85 9 10
90 0
95 9 10
105 31 34
115 62 61
125 103 93
135 172 133
145 251 157
155 356 163
165 452 126
175 467 44
180 467
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-
30 323 20.0
0- 40 475 29.4
0- 60 692 42.8
0- 90 795 49.2
90-120 105 6.5
90-130 198 12.3
90-150 488 30.2
90-180 822 50.8
0-180 1617 100.0
TOTAL INPUT WATTS = 33.0
EFFICACY = 49.0 Lm/W
CIE TYPE - DIRECT-INDIRECT
LUMINAIRE SPACING CRITERION = 1.0
220
440
220
440
15˚ 30˚ 45˚
60˚
75˚
90˚
180˚ 165˚ 150˚ 135˚
120˚
105˚
90˚
P-/K
LED Light Engine:  K  CRI
System Wattage: 
Fixture delivered lumens: 
Fixture Efficacy: .
Spacing Criteria: 
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-30 323 20.0
0-40 475 29.4
0-60 692 42.8
0-90 795 49.2
90-120 105 6.5
90-130 198 12.3
90-150 488 30.2
90-180 822 50.8
0-180 1617 100.0
CANDELA DISTRIBUTION
DEG CANDELA LUMENS

 
  
  
  
  
  
  
  
 

 
  
  
  
  
  
  
  
  
 
Test . Test Date //
Cylinder
Wall Mounted • Damp Location Listed