Installation Guide
&XVWRPHU6HUYLFH
Page 1 of 3
SPEC. NO. 93060814 
P5641, P5643, P5644, P5642,  
P5674 & P5675 SERIES 
Assembly & Installation Instructions
CAUTION: 
Read instructions carefully and turn electricity off at main circuit breaker panel before beginning 
installation.
WARNING: Follow the instructions carefully to assure full compliance with local, state, and NEC requirements. If there are any 
questions, contact a Qualified Electrical Contractor.
WARNING: Risk of fire or electrical shock. Install this kit only in the Recessed Cans matching the dimensions listed below.
WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
CAUTION: Risk of fire. Consult a Qualified Electrician to ensure correct branch circuit conductor.
NOTE: This product is designed to operate with most standard incandescent or low voltage electronic dimmer switches. 
Results may vary. For recommended dimmers, consult product specification sheet for more details.
NOTE: SUITABLE FOR DAMP LOCATIONS. SUITABLE FOR WET LOCATIONS WITH TOP COVER “K” ASSEMBLED: 
P5642-XX USE P8798, P5642-XX30K USE P860039, P5644 USE P8797, P5675-XX USE P8799, 
P5675-XX30K USE P860038, P5713 USE P8799 
WARNING: To comply with the National Electric Code and Underwriters Laboratories requirenents, the edge of the wall plate coming 
in contact with the mounting surface, must be sealed with a latex waterproof caulking to prevent water from entering the oulet box. 
NOTE: Always install with ambient temperatures specified on the product specification sheet. 5 year warranty with product 
registration. See www.progresslighting.com for details.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
THIS PR
ODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 
FAMILIAR WITH 
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 
NOTE: On up/down models, the wiring connections can be wired together or 
separated and controlled by two separate switches.
OR
BLACK SUPPLY 
WIRE
WHITE SUPPLY 
WIRE
WHITE OR IDENTIFIED 
FIXTURE WIRE
PLAIN OR BLACK 
FIXTURE WIRE
BARE, OR GREEN 
GROUND WIRE 
FROM SUPPLY
GREEN GROUND 
SCREW
UL LISTED 
WIRENUTS
BARE, OR GREEN 
GROUND WIRE 
FROM SUPPLY
BARE, OR GREEN 
FIXTURE GROUND 
WIRE
CAUTION: All glass is fragile, use care when 
handling glass components. 
1. Fasten mounting plate (A) to outlet box (B) with 
mounting screws (C) from outlet box (B). Thread 
green ground screw (D) into mounting plate (A). 
2. Connect fixture wires (E) to supply wires (F) as 
shown on wiring diagram. 
3. Slip fixture assembly (G) over mounting plate (A) 
and secure in place with screw(s) (H). Use wrench (J) 
to tighten set screw.
see note 
below
K
G
A
F
B
C
D
H
J
E