Specification Sheet

P563001-020-30K
Photometrics:
ELECTRICAL DATA P563001-020-30K
Input Voltage  V
Input Frequency  Hz
Input Current . A
THD <%
EMI/RFI FCC Title , Part , Class B
Operating Temperature - °C
Dimming Yes*
Over-voltage, over-current, short-circuit protected
*See Dimming Notes for more information
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 17.02586 PAGE: 4 OF 9
ISSUE DATE: 09/22/17
PREPARED FOR: PROGRESS
CATALOG NUMBER: P563000-147-30K
DEG CANDELA LUMENS
0 451
5 448 43
15 435 123
25 401 185
35 350 218
45 239 183
55 113 103
65 39 40
75 10 12
85 1 1
90 0
95 0 0
105 1 1
115 1 1
125 4 3
135 6 16
145 345 198
155 412 190
165 435 123
175 463 44
180 477
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 351 23.6
0- 40 568 38.3
0- 60 855 57.6
0- 90 908 61.2
90-120 2 0.1
90-130 6 0.4
90-150 220 14.8
90-180 576 38.8
0-180 1484 100.0
EFFICACY = 61.6 lm/W
CIE TYPE - SEMI-DIRECT
LUMINAIRE SPACING CRITERION = 1.25
PLANE : 0-DEG 90-DEG
SHIELDING ANGLES : 90 90
240
480
240
480
15˚ 30˚ 45˚
60˚
75˚
90˚
105˚
120˚
135˚150˚165˚180˚
P--K
LED Light Engine:  K  CRI
System Wattage: 
Fixture delivered lumens: 
Fixture Efficacy: 
Spacing Criteria: .
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-30 351 23.6
0-40 568 38.3
0-60 855 57.6
0-90 908 61.2
90-120 2 0.1
90-130 6 0.4
90-150 220 14.8
90-180 576 38.8
0-180 1484 100.0
CANDELA DISTRIBUTION
DEG CANDELA LUMENS

 
  
  
  
  
  
  
  






 
  
  
  
  
 
Test . Test Date //
Cylinders
Wall Mounted • Wet Location Listed