Specification Sheet
Photometrics:
One-Light Pendant
Ceiling chain or stem mounted • Damp location listed
PK
ELECTRICAL DATA P-K
Input Voltage V
Input Frequency Hz
Input Current . A
Input Power
Power Factor Greater than .
THD <%
FCC Meets FCC Title , Part Class B
Operating Temperature - °C to °C
Dimming Yes*
*See Dimming Notes for more information
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 17.03021 PAGE: 4 OF 9
ISSUE DATE: 12/01/17
PREPARED FOR: PROGRESS
CATALOG NUMBER: P350113-108-30
DEG CANDELA LUMENS
0 375
5 372 35
15 353 99
25 314 145
35 263 164
45 202 156
55 142 127
65 90 90
75 50 53
85 19 22
90 9
95 3 4
105 3 3
115 3 3
125 2 2
135 1 1
145 1 1
155 0 0
165 0 0
175 0 0
180 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 279 30.9
0- 40 444 49.0
0- 60 727 80.3
0- 90 891 98.4
90-120 10 1.1
90-130 12 1.4
90-150 14 1.6
90-180 14 1.6
0-180 905 100.0
EFFICACY = 51.4 lm/W
CIE TYPE - DIRECT
SPACING CRITERION: 1.16
130
260
390
0˚ 15˚ 30˚
45˚
60˚
75˚
90˚
LEGEND
0-deg
P-K
LED Light Engine: K CRI CRI
System Wattage:
Fixture delivered lumens:
Fixture Efficacy: .
Spacing Criteria: .
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
NVLAP LAB CODE: 201003-0
®
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
PAGE: 2 OF 7 REPORT NUMBER: 8888
ISSUE DATE: 04/10/14
PREPARED FOR: PROGRESS
CATALOG NUMBER: P5188-0930K9
LUMINAIRE: 1-LT. PENDANT, 17W LED MODULE
LAMP: 1- HAL LED WAFER
BALLAST: NO DRIVER REQUIRED
MOUNTING: PENDANT
NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED.
ACCREDITED LABORATORY CODE 201003-0
DEG CANDELA LUMENS
0 455
5 401 38
15 369 103
25 300 140
35 239 154
45 209 157
55 121 109
65 51 52
75 17 19
85 4 5
90 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 281 36.2
0- 40 435 55.9
0- 60 701 90.2
0- 90 777 100.0
90-180 0 0.0
0-180 777 100.0
TOTAL INPUT WATTS = 16.1
EFFICACY = 48.3 Lm/W
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 0.9
LUMINOUS DIAMETER: 10.000
LUMINANCE DATA IN CANDELA/SQ METER
ANGLE AVERAGE
IN DEG
45 5831.
55 4162.
65 2381.
75 1296.
85 905.
Approved
Checked
160
320
480
0˚ 15˚ 30˚
45˚
60˚
75˚
90˚
D. BLACK
M. WASHBURN
P-K
LED Light Engine: K CRI
System Wattage:
Fixture delivered lumens:
Fixture Efficacy: .
Spacing Criteria: .
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-30 281 36.2
0-40 435 55.9
0-60 701 90.2
0-90 777 100.0
90-180 0 0.0
0-180 777 100.0
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
Test Test Date //



