Specification Sheet

Photometrics:
One-light Pendant
Ceiling cord mounted • Damp location listed
P
ELECTRICAL DATA P--
Input Voltage  V
Input Frequency  Hz
Input Current
Input Power 
Power Factor
THD <%
FCC FCC Title , Part , Class B
Operating Temperature - °C to
Dimming Yes*
*See Dimming Notes for more information
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 17.03021 PAGE: 4 OF 9
ISSUE DATE: 12/01/17
PREPARED FOR: PROGRESS
CATALOG NUMBER: P350113-108-30
DEG CANDELA LUMENS
0 375
5 372 35
15 353 99
25 314 145
35 263 164
45 202 156
55 142 127
65 90 90
75 50 53
85 19 22
90 9
95 3 4
105 3 3
115 3 3
125 2 2
135 1 1
145 1 1
155 0 0
165 0 0
175 0 0
180 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 279 30.9
0- 40 444 49.0
0- 60 727 80.3
0- 90 891 98.4
90-120 10 1.1
90-130 12 1.4
90-150 14 1.6
90-180 14 1.6
0-180 905 100.0
EFFICACY = 51.4 lm/W
CIE TYPE - DIRECT
SPACING CRITERION: 1.16
130
260
390
15˚ 30˚
45˚
60˚
75˚
90˚
LEGEND
0-deg
P--
LED Light Engine:  K  CRI CRI
System Wattage: 
Fixture delivered lumens:
Fixture Efficacy:
Spacing Criteria:
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 18.00160 PAGE: 4 OF 5
ISSUE DATE: 02/14/18
PREPARED FOR: PROGRESS
CATALOG NUMBER: P500148--009-30
DEG CANDELA LUMENS
0 59.3
5 59.4 6
15 59.5 17
25 58.8 27
35 57.5 36
45 55.1 43
55 51.9 47
65 47.8 47
75 42.7 45
85 37.8 41
90 34.5
95 31.7 35
105 25.6 27
115 19.6 20
125 14.3 13
135 9.4 7
145 5.4 3
155 2.5 1
165 0.9 0
175 0.0 0
180 0.0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 50 12.0
0- 40 86 20.7
0- 60 175 42.1
0- 90 309 74.4
90-120 82 19.6
90-130 94 22.7
90-150 105 25.3
90-180 106 25.6
0-180 415 100.0
EFFICACY = 44.6 lm/W
CIE TYPE - SEMI-DIRECT
PLANE : 0-DEG 90-DEG
:12.000 12.000LUMINOUS DIAMETER
HEIGHT OF SIDE : 6.000 6.000
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE
IN DEG
45 559.
55 568.
65 587.
75 620.
85 695.
20
40
60
15˚ 30˚
45˚
60˚
75˚
90˚
LEGEND
0-deg
P--
LED Light Engine:  K  CRI
System Wattage: 
Fixture delivered lumens: 
Fixture Efficacy: .
Spacing Criteria:
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-30 50 12.0
0-40 86 20.7
0-60 175 42.1
0-90 309 74.4
90-120 82 19.6
90-130 94 22.7
90-150 105 25.3
90-180 106 25.6
0-180 415 100.0
CANDELA DISTRIBUTION
DEG CANDELA LUMENS
.
.
 . 
 . 
 . 
 . 
 . 
 . 
 . 
 . 
 .
 . 
 . 
 . 
 . 
 .
 .
 .
 .
 .
 .
Test . Test Date //