The Access Point One S receives the scanned barcode
data from MARK 2 via 868/915 MHz. This barcode data
is transmitted to the end device via USB cable or RS232
cable. In the USB HID mode, the Access Point One S simu-
lates a computer keyboard. A standard connection is em-
ulated in the USB CDC mode. In order to use the USB CDC
mode,  under “Device settings - Output
-
ration tool. More detailed information about the conversion can

A RS232 cable establishes a serial connection between
Access Point One S and the end device.
MECHANICAL PROPERTIES:
Dimensions: ........................... 
Weight: ................................... 100g
ELECTRONIC PROPERTIES:
Power supply of Access
Point One S via USB cable: ...
5 VDC (0.5A)
via host computer
Power supply of Access
Point One S via RS232
cable: .....................................
12 VDC (1A)
via power supply PG12-10P55
RADIO TRANSMISSION:
Encryption: ............................. AES-128
Transmission range: ............. up to 30m
within a building
ENVIRONMENTAL
CONDITIONS:
Protection against dust and
water: ..................................... IP22
Working temperature: ........... -23°F to +122°F
ACCESS POINT ONE S
OVERVIEW TECHNICAL DATA
LED Label with serial number
Pairing
Barcode
Cable release
opening
RJ45 socket