Instructions / Assembly
20
MAINTENANCE
Regular maintenance is important for optimal 
performance and to reduce wear. Inspect and properly 
tighten all parts each time the elliptical is used. 
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small 
amount of mild soap. IMPORTANT: To avoid damage 
to the console, keep liquids away from the console 
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not display your heart rate when 
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see 
step 8 on page 15. 
If a replacement power adapter is needed, call the 
telephone number on the cover of this manual. 
IMPORTANT: To avoid damaging the console, use 
only a manufacturer-supplied regulated power 
adapter.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the 
reed switch should be adjusted. To adjust the reed 
switch, first unplug the power adapter. 
Remove the 
four M4 x 16mm 
Screws (not 
shown) from the 
Large Storage 
Foot (27), and 
then remove the 
Large Storage 
Foot. Remove the 
two M4 x 16mm 
Screws (not 
shown) from the 
Top Shield (37), and then use a standard screwdriver 
to pry the Top Shield upward off the elliptical.
Look into the access opening and locate the Reed 
Switch (58). Rotate the Pulley (66) until a Magnet (41) 
is aligned with the Reed Switch. Note: For clarity, the 
shields are shown removed in the drawing below.
Slightly loosen the two indicated M4 x 16mm Screws 
(61). Slide the Reed Switch (58) slightly toward or 
away from the Magnet (41). Then, retighten the 
M4 x 16mm Screws.
Plug in the power adapter and rotate the pulley for a 
moment. Repeat these actions until the console dis-
plays correct feedback. 
When the reed switch is correctly adjusted, unplug 
the power adapter and reattach the parts that you 
removed. Then, plug in the power adapter.
37
27
66
58
41
61
MAINTENANCE AND TROUBLESHOOTING