Specifications

JiaXing Jarol Scientific Instrument Co.,Ltd JR 6 000 series product s
94
mode
0: Stop after one cycle: Inverter stops
automatically as soon as it completes one cycle,
and it needs run command to start again.
1: Hold last frequency after one cycle: Inverter
holds frequency and direction of last step after
one cycle.
2: Circular run: Inverter continues to run cycle by
cycle until receive a stop command.
Acceleration time
(2 steps)
FA.03
FA.05
FA.07
FA.06
FA.02
FA.04
Deceleration time
(2 steps)
FA.28
FA.30
FA.32
FA.31
FA.33
Figure 6. 24 Simple PLC operation diagram.
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
FA.01
Simple PLC
status saving
after power off
0~1 0
0 Power loss without memory
1 Power loss memory
PLC record the running stage and frequency when
power loss .
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
FA.02
Multi-step
speed 0
-100.0~100.0%
0.0%
FA.03
0 th running
time
0.0~6553.5s
0.0s
FA.04
Multi-step
speed 1
-100.0~100.0%
0.0%
FA.05
1 th running
time
0.0~6553.5s
0.0s
FA.06
Multi-step
speed 2
-100.0~100.0%
0.0%
FA.07
2 th running
time
0.0~6553.5s
0.0s
FA.08
Multi-step
speed 3
-100.0~100.0%
0.0%
FA.09
3 th running
time
0.0~6553.5s
0.0s
FA.10
Multi-step
speed 4
-100.0~100.0%
0.0%
FA.11 4 th running 0.0~6553.5s