Specifications

JiaXing Jarol Scientific Instrument Co.,Ltd JR 6 000 series product s
88
Figure 6.2 0 Frequency arriving detection
diagram .
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F8.24 Droop control
0.00~10.00Hz
0.00Hz
When several motors drive the same load, each
motor's load is different because of the difference
of motor's rated speed. The load of different
motors can be balanced through droop control
function which makes the speed droop along with
load increas e . When the motor outputs rated
torque, actual frequency drop is equal to F 8.24.
User can adjust this parameter from small to big
gradually during commissioning. The relation
between load and output frequency is in the
following figure.
Figure 6 .21 Droop control diagram .
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F8.25
Brake
threshold
voltage
115.0~140.0%
Depand on
Model
When the DC bus voltage is greater than the value
of F 8.2 5 , the inverter will start dynamic braking.
Notice:
Notice:
Notice:
Notice:
Factory
Factory
Factory
Factory setting
setting
setting
setting is
is
is
is 120%
120%
120%
120% if
if
if
if rated
rated
rated
rated voltage
voltage
voltage
voltage
of
of
of
of inverter
inverter
inverter
inverter is
is
is
is 220V.
220V.
220V.
220V.