Specifications

JiaXing Jarol Scientific Instrument Co.,Ltd JR 6 000 series product s
82
line speed
1.0%
This parameter is used to calculate the line speed
based on actual mechanical speed. The formula is
as below:
Line speed = actual mechanical speed * F 7.10
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F7.11
Rectify module
temperature
0~100.0
F7.12
IGBT module
temperature
0~100.0
F7.13 Software version
F7.14
Inverter rated
power
0~3000kW
Depend on
model
F7.15
Inverter rated
current
0.0~6000A
Depend on
model
F7.16
Accumulated
running time
0~65535h
Rectify module temperature: Indicates the
temperature of rectify module. Overheat
protection point of different model may be
different.
IGBT module temperature: Indicates the
temperature of IGBT module. Overheat protection
point of different model may be different.
Software version: Indicates current software
version of DSP .Accumulated running time:
Displays accumulated running time of inverter.
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F7.17
Third latest
fault type
0~2 5
F7.1 8
Second latest
fault type
0~2 5
F7.1 9
Latest fault
type
0~2 5
These parameters record three recent fault types.
0 means there is no fault and 0~2 5 means there
are 25 faults. For details, please refer to fault
analysis.
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F7.20
Output
frequency at