Specifications
JiaXing Jarol Scientific Instrument Co.,Ltd - JR 6 000 series product s
80
status display
selection 1
【 0x07FF 】
When the JR6000 series frequency inverter
running,parameter display effect by function
code ,If Bit is 1, the parameter will be displayed.
Press 》 /SHIFT to scroll through these
parameters in right order . Press DATA/ENT +
QUICK/JOG to scroll through these parameters in
left order.
The display content corresponding to each bit of
F7.06 is described in the following table:
BIT15 BIT14 BIT13 BIT12 BIT11 BIT10
Step No.
of PLC
or
multi-ste
p
Count
value
T
orque
setting
value
Output
terminal
status
Input
terminal
status
PID
feedba
ck
BIT9 BIT8 BIT7 BIT6 BIT5 BIT4
PID
preset
Output
torque
Output
power
Line
speed
Rotation
speed
Output
current
BIT3 BIT2 BIT1 BIT0
Output DC bus Refere R unning
voltage voltage nce
freque
ncy
frequenc
y
Input /output terminal condition display by into
the system , S1 ( HDO ) as lowest position For
example inputposition display 3,means S1 ,S2
always close,other terminal break,the detailed
information please check F7.23 and F7.24
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F7.07
Running
status display
selection 2
0~0xFFFF
【 0x0000 】
The display content corresponding to each bit of
F7. 8 is described in the following table:
BIT15 BIT14 BIT13 BIT12 BIT11 BIT10
Reserve
d
Reserv
ed
Reserv
ed
Reserv
ed
Reserv
ed
Reserved
BIT9 BIT8 BIT7 BIT6 BIT5 BIT4
Reserve
d
Reserv
ed
Reserv
ed
Reserv
ed
Reserv
ed
I nverter
overload