Specifications
JiaXing Jarol Scientific Instrument Co.,Ltd - JR 6 000 series product s
76
code
code
code
code
F6.04
AO 1 function
selection
0~1 0 【 0 】
F6.05
AO2 function
selection
0~1 0 【 0 】
F6.06
HDO function
selection
0~1 0 【 0 】
Standard output the analog value is 0~20mA
( or 0~10V ), AO1 can select current/voltage by
jumper J3 , AO2 can select current/voltage by
jumper J4 。 HDO input plause from 0kHz to
50.00kHz setting.
Setting
Setting
Setting
Setting
Value
Value
Value
Value
Function
Function
Function
Function Range
Range
Range
Range
0
Running
frequency
0~ M aximum frequency
1
Reference
frequency
0~ M aximum frequency
2
Running
speed
0~2* rated
synchronous speed of
motor
3 Output 0~2* inverter rated
current current
4
Output
voltage
0~1.5* inverter rated
voltage
5
Output
power
0~2* rated power
6
S etting
torque
0~2*rated current of
motor
7
Output
torque
0~2*rated current of
motor
8 AI1 voltage 0~10V
9
AI2
voltage/cur
rent
0~10V/0~20mA
10
HDI
frequency
0.1~50.0kHz
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F6.07 AO1 lower limit
0.0~100.0%
【 0.0% 】
F6.08
AO1 lower limit
corresponding
0.00~10.00V
【 0.00V 】