Specifications
JAROL Assumes the promotion of energy-saving technology as its own task!
75
F6.01
HDO ON-OFF
output
selection
0~2 0 【 1 】
F6.02
Relay 1 output
selection
0~2 0 【 4 】
F6.03
Relay 2 output
selection
(4.0kW and
above)
0~2 0 【 0 】
OC/Relay output functions are indicated in
the following table :
0 : No output .
1 : Running , ON: Run command is ON or voltage
is being output.
2 : Run forward , ON: During forward run.
3 : Run reverse , ON: During reverse run.
4 : Fault output , ON: Inverter is in fault status.
5 : FDT reached , Please refer to description of
F8.21, F8.22.
6 : Frequency reached , Please refer to description
of F8.23.
7 : Zero speed running , ON: The running frequency
of inverter and setting frequency are zero.
8 : Preset count value reached , Please refer to
description of F8.18.
9 : Specified count value reached , Please refer to
description of F8.19.
10 : overload pre-warming of inverter , Please refer
to description of Fb.04~Fb.06
11 : Simple PLC step completed
, After simple PLC completes one step, inverter
will output ON signal for 500ms.
12 : PLC cycle completed , fter simple PLC
completes one cycle, inverter will output ON signal
for 500ms.
13 : Running time reached , ON: The accumulated
running time of inverter reaches the value of
F8.20.
14 : Upper frequency limit reached , ON:
Running frequency reaches the value of F0.04.
15 : Lower frequency limit reached , ON:
Running frequency reaches the value of F0.05.
16 : Ready , ON: Inverter is ready (no fault,
power is ON).
17~20 : Reserved
Function
Function
Function
Function Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range