Specifications
JiaXing Jarol Scientific Instrument Co.,Ltd - JR 6 000 series product s
66
Figure 6-7 V/F Curve
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F4.01 Torque boost
0.0~10.0 %
【 0.0 %】
F4.02
Torque boost
cut-off
0.0~50.0 %
【 20.0 %】
Torque boost will take effect when output
frequency is less than cut-off frequency of torque
boost ( F 4.0 2 ). Torque boost can improve the
torque performance of V/F control at low speed.
The value of torque boost should be determined
by the load. The heavier the load, the larger the
value is . I f the boost is too large, the motor will run
in exciting. T he efficiency of the motor decreases
as the current of the inverter increases and the
motor increase the heat-releasing.
W hen the torque boost is set to 0.0% , the inverter
is in the automatic torque boost state.
Cut-off point of torque boost : the torque boost
is valid under this point, and the torque boost is
invalid when exceeding this set frequency.
Figure 6-8 Torque boost by hand
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F4.03
V/F
frequency 1
0.00~F4.05
【 0 .00Hz 】
F4.04 V/F voltage 1
0.0~100.0 %
【 0.0 %】
F4.05
V/F
frequency 2
F4.03~F4.07
【 0 .00Hz 】
F4.06 V/F voltage 2
0.0~100.0 %
【 0.0 %】