Specifications
JiaXing Jarol Scientific Instrument Co.,Ltd - JR 6 000 series product s
62
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
model 】
Note:
Note:
Note:
Note: In
In
In
In order
order
order
order to
to
to
to achieve
achieve
achieve
achieve superior
superior
superior
superior
performance,
performance,
performance,
performance, please
please
please
please set
set
set
set these
these
these
these parameters
parameters
parameters
parameters
according
according
according
according to
to
to
to motor
motor
motor
motor nameplate,
nameplate,
nameplate,
nameplate, and
and
and
and then
then
then
then
perform
perform
perform
perform autotuning.
autotuning.
autotuning.
autotuning.
T he inverter provides parameters autotune.
C orrect parameters autotune is from the right
setting of parameter of motor. The power rating of
inverter should match the motor. If the bias is too
big, the control performances of inverter will be
deteriorated distinctly.
Reset
Reset
Reset
Reset F
F
F
F 2.0
2.0
2.0
2.0 1
1
1
1 can
can
can
can initialize
initialize
initialize
initialize F2.06~F2.10
F2.06~F2.10
F2.06~F2.10
F2.06~F2.10
automatically.
automatically.
automatically.
automatically.
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F2.06
Motor stator
resistance
0.001~65.535 Ω
【 Depend on
model 】
F2.07
Motor rotor
resistance
0.001~65.535 Ω
【 Depend on
model 】
F2.08
Motor leakage
inductance
0.1~6553.5mH
【 Depend on
model 】
F2.09
Motor mutual
inductance
0.1~6553.5mH
【 Depend on
model 】
F2.10
Current without
load
0.1~6553.5A
【 Depend on
model 】
After autotuning, the value of F2.06 - F2.10 will be
automatically updated. These parameters are the
basic parameters for high performance V/F control
which have direct impact to the control
performance.
Note:
Note:
Note:
Note: Do
Do
Do
Do not
not
not
not change
change
change
change these
these
these
these parameters;
parameters;
parameters;
parameters;
otherwise
otherwise
otherwise
otherwise it
it
it
it may
may
may
may deteriorate
deteriorate
deteriorate
deteriorate the
the
the
the control
control
control
control
performance
performance
performance
performance of
of
of
of inverter.
inverter.
inverter.
inverter.
F3
F3
F3
F3 Group
Group
Group
Group Vector
Vector
Vector
Vector Control
Control
Control
Control
Function
Function
Function
Function
code
code
code
code
Name
Name
Name
Name Setting
Setting
Setting
Setting range
range
range
range
F3.00
ASR
proportional
gain Kp1
0~100 【 20 】