Specifications

JiaXing Jarol Scientific Instrument Co.,Ltd JR 6 000 series product s
46
status.
5.3
5.3
5.3
5.3 Running
Running
Running
Running State
State
State
State
5.3.1 Power-on initialization
Firstly the system initializes during the inverter
power-on, and LED displays JAROL . After the
initialization is completed, the inverter is in
stand-by status
5.3.2 Stand-by
In stop or running status, multi-status
parameters can be displayed. And these function
can be choose to display through function code
F7.06 and F 7.07 (running parameters) and
F7.08(stop parameters) at the bineary bits. See
the description of F7.06, F7.07 andF7.08 for
detailed definition.
In stop status, there are ten stopping parameters
which can be chosen to display or not. They are:
reference frequency, DC bus voltage, ON-OFF
input status, open collector output status, PID
setting, PID feedback, analog input AI1 voltage,
analog input AI2 voltage, HDI frequency, step
number of simple PLC and multi-step speed.
Whether or not to display depends on setting the
corresponding binary bit of F7.08. Press the
/SHIFT to scroll through the parameters in right
order. Press DATA/ENT + QUICK/JOG to scroll
through the parameters in left order.
5.3.3
5.3.3
5.3.3
5.3.3 Operation
In running status, there are nineteen running
parameters which can be chosen to display or not.
They are: running frequency, reference frequency,
DC bus voltage, output voltage, output current,
rotating speed, line speed, output power, output
torque, PID setting, PID feedback, ON-OFF input
status, open collector output status, length value,
count value, step number of PLC and multi-step
speed, voltage of AI1, voltage of AI2, high speed
pulse input HDI frequency. Whether or not to
display depends on setting the corresponding bit
of F 7.06, F 7.07. Press the /SHIFT to scroll
through the parameters in right order. Press
DATA/ENT + QUICK/JOG to scroll through the
parameters in left order.
5.3.4
5.3.4
5.3.4
5.3.4 Fault
Fault
Fault
Fault