Specifications

JiaXing Jarol Scientific Instrument Co.,Ltd JR 6 000 series product s
26
following figure.
4.2.5
4.2.5
4.2.5
4.2.5 Wiring
Wiring
Wiring
Wiring at
at
at
at inverter
inverter
inverter
inverter side
side
side
side of
of
of
of
main
main
main
main circuit
circuit
circuit
circuit
DC
DC
DC
DC reactor
reactor
reactor
reactor
JR6000 series inverters from 18.5kW to 90kW
(380V) are equipped with internal DC reactors
for the improvement of power factors and the
avoidance of damage from high input current to
the rectifying components because of the
high-capacity transformer. The inverter can also
cease the damage to the rectifying components
which are caused by supply net voltage
transients and harmonic waves of the loads.
Braking
Braking
Braking
Braking unit
unit
unit
unit and
and
and
and braking
braking
braking
braking resistor
resistor
resistor
resistor
JR6000 series inverters below 1 5 kW (380V) are
equipped with internal braking unit. In order to
dissipate the regenerative energy generated by
dynamic braking, the braking resistor should be
installed at (+) and P R terminals.
The wire length of the braking resistor should
be less than 5m.
Please pay attention to safety prevention and
smooth ventilation when installing braking
resistors because the temperature will rise for
the heat releasing.
The (+) and (-) terminal of the braking units
corresponds to the (+) and (-) terminal of the
inverter when the external braking unit is
connected. Connect braking resistor to the BR1
and BR2 terminal of the braking unit.
The wiring length between the ( +) , (-) terminals
of the inverter and the (+) (-) terminals of the
braking units should be no more than 5m and
the distributing length among BR1 and BR2 and
the braking resistor terminals should be no more
than 10m.
Note:
Note:
Note:
Note: Be
Be
Be
Be sure
sure
sure
sure that
that
that
that the
the
the
the electric
electric
electric
electric polarity
polarity
polarity
polarity of
of
of
of (+)
(+)
(+)
(+)
(-)
(-)
(-)
(-) terminals
terminals
terminals
terminals is
is
is
is right;
right;
right;
right; it
it
it
it is
is
is
is not
not
not
not allowed
allowed
allowed
allowed to
to
to
to
connect
connect
connect
connect (+)
(+)
(+)
(+) with
with
with
with (-)
(-)
(-)
(-) terminals
terminals
terminals
terminals directly,
directly,
directly,
directly,
otherwise
otherwise
otherwise
otherwise damage
damage
damage
damage or
or
or
or fire
fire
fire
fire may
may
may
may occur.
occur.
occur.
occur.
4.
4.
4.
4. 2
2
2
2 .
.
.
. 6
6
6
6 Wiring
Wiring
Wiring
Wiring of
of
of
of main
main
main
main loop
loop
loop
loop on
on
on
on
output
output
output
output side
side
side
side
Connection
Connection
Connection
Connection between
between
between
between inverter
inverter
inverter
inverter and
and
and
and