Installation manual

53
EN
Wiring the Inverter
Inverter
Next tighten the cable gland body to connector housing and the
cable gland cap to the cable gland body . Tightening torque for
cable sheath diameters between 22 and 32 mm: 6 to 8 Nm. Rotate
the coupling ring to mate the connector with the inverter‘s AC plug.
After wiring the mating connector, screw the
connector housing to the coupling ring . To
do this push the coupling ring to the connec-
tor housing and tighten 1-2 Nm.
Rotate the connector housing and cable
gland body and cable gland cap to
remove them from the coupling ring.
The female cable
connector needs to
be wired as shown
below.
To wire the connector refer to placement
of L1, L2, L3, N and PE shown to the left.
Screw termination is provided to x the
wires to the contacts.
NOTE: Rear
view of cable
connector
L1
L2
L3
N
PE
Cable
Slide the connector housing, cable gland
body and cable gland cap onto the cable.
L3
L1
L2
N
PE
Cable
Figure 6.7.: AC connector for 30 TL