Technical data
OPERATING CONDITIONS & REQUIREMENTS
Page 4
OPERATING PRESSURE: min. 1,4 / max. 8,3 bar
this system is configured to perform optimally at an operating
pressure of 3 bar (±½ bar); in case of a lower or higher operating
pressure the performance may be affected negatively!
check water pressure regularly.
take into account that night time water pressure may be
considerably higher than day time water pressure.
install a pressure reducer ahead of the water softener if
necessary.
OPERATING TEMPERATURE: min. 2 / max. 48 °C
do not install the water softener in an environment where high
ambient temperatures (e.g. unvented boiler house) or freezing
temperatures can occur.
the water softener cannot be exposed to outdoor elements,
such as direct sunlight or atmospheric precipitation.
do not install the water softener too close to a water heater;
keep at least 3 m of piping between the outlet of the water
softener and the inlet of the water heater; water heaters can
sometimes transmit heat back down the cold pipe into the
control valve; always install a check valve at the outlet of the
water softener.
ELECTRICAL CONNECTION: 230V-50Hz
this water softener only works on 24VAC; it is equipped with a
230/24V-50Hz transformer; always use it in combination with
the supplied transformer.
make sure to plug the transformer into a power outlet, which is
installed in a dry location, with the proper rating and over-
current protection.