ProFloSE Downflow
Master Programming Mode (Cont’d.)
3. Treated Water Capacity (No Display Code)
Depress the Extra Cycle Button. This display is used to set the amount of treated water (gallons/liters) that can be produced by
the unit before a regeneration cycle is required. With Meter Delayed Regeneration Type set, it will be up to the programmer to
determine a reserve capacity and subtract that value from the calculated full capacity of the unit. This display will not be
viewed with Timeclock Regeneration Type set.
Example: Regenerates every 700 gallons or liters -
[ 7 0 0 ]
The Set UP and DOWN Buttons will adjust this value.
4. Regeneration Time (No display Code)
Depress the Extra Cycle Button. The next display viewed is the option setting for Regeneration Time. It is identified by a non-
flashing colon between two sets of numbers. Set the desired time of day that a regeneration may occur, if required. This display
will not be viewed with Meter Immediate Regeneration Type set.
Example: 2 o’clock A.M. regeneration time -
[ 2 : 0 0 ] (A.M. Indicator Dot On)
The Set UP and DOWN Buttons will adjust this value.
5. Regeneration Day Override (A)
Depress the Extra Cycle Button. This display is used to set the maximum amount of time (in days) the unit can be in service
without a regeneration. This option setting is identified by the letter ‘A’ in the first digit. With Meter Immediate Regeneration
Type selected, regeneration will begin at the same point in time some amount of days ago when the last regeneration cycle was
initiated. With Timeclock or Meter Delayed Regeneration Types selected, regeneration begins at the set Regeneration Time.
An OFF setting will cancel this feature with all regeneration types except Timeclock Regeneration were it must be used.
Example: Override every 7 days -
[ A - - 7 ]
Cancel setting - [ A O F F ] (Meter Immediate or Delayed Regeneration Types Only)
The Set UP and DOWN Buttons will adjust this value.
6. Regeneration Cycle Step Programming (1) (2) (3) (4) (5) (6)
Depress the Extra Cycle Button. The next 2-4 displays viewed are part of a series of option settings used to program the
Regeneration Cycle. Up to 4 steps can be programmed. Each display is used to set the duration time in minutes (or tenths of
minutes - Metric) of that specific step in a regeneration cycle. A step # will turn on for the regeneration cycle step being
programmed. Regeneration steps are skipped by setting the display to 0 and regeneration ended by setting the step # after the
last active step to OFF, as shown below and on the next page:
Examples: Regeneration Cycle Step #1 - 8 minutes -
[ 1 - - 8 ]
Regeneration Cycle Step #3 - skipped - [ 3 - - 0 ]
Example: lbs. salt ÷ 3 ÷ B.L.F.C. Size = refill time in minutes, 10 lbs. salt ÷ 3 ÷ .25 = 13.3 minute refill
The Set UP and DOWN Buttons will adjust these values.