Specifications

| 8 | ProFlow Eliminator
Hardness Setting
Move the jumper to the set of pins next to the word
HARDNESS (8). Press the black TIME SET bu on until the
hardness of the incoming water supply is displayed. The
hardness range is from 1 to 99 grains per gallon.
To change water hardness stated in parts per million
(PPM) to grains per gallon (GPG) use this formula:
Capacity Setting
Move the jumper to the set of pins next to the word
CAPACITY (9). Press the black TIME SET bu on until the
correct capacity value is displayed. The capacity range is 1
to 99 kilograins. Refer to the Suggested Salt Dial Se ings
table (8).
Return the jumper to the top set of pins next to the word
TIME and replace the access door. The jumper must
NOT be le on any pins other than the top pair next to
the word TIME. Otherwise, the unit may show a blank
display.
Note: A spare jumper is located on the bo om set of pins.
In the event that the hardness or capacity se ing must be
changed, simply follow the appropriate steps described
above.
Calendar Override Setting
1. Disconnect power.
2. Place jumper on Pin A and reconnect power.
3. Move jumper to Pin B. A zero will appear, indicating
zero days of calendar override. All controllers are
preprogrammed in this manner at the manufacturer.
Note: System comes pre-programmed with default
hardness, capacity and corresponding salt se ings. Refer
to table 1 for default se ings.
4. Depress the black TIME SET bu on. The numbers will
roll from “0” to “15.” Release the switch at the desired
number of days for the calendar override. For example,
releasing the switch at “10” would program a 10-day
calendar override.
5. Disconnect power.
6. Place jumper back on TIME and reconnect power.
7. The calendar override program is maintained during
power outages by the NOVRAM circuitry.
8. To remove the calendar override, follow the same
steps above and program back to “0.
ppm = gpg
17.1
Figure 6 Figure 8 Figure 9
Figure 9: Indicator Knob
Indicator Knob
Common Features
Salt Dial Adjustment
These models may be adjusted to produce maximum to
minimum conditioning capacities by se ing the salt dial,
which controls the amount of salt used per regeneration.
When desired, the minimum se ing may be used on
installations if the frequency of regeneration is increased
to compensate for lower regenerated conditioning
capacity. The installing dealer will set the unit for proper
salt usage. Further adjustments are needed only if the
hardness of the water supply changes or if water use
changes dramatically. Capacity will need to be adjusted
accordingly.
To adjust salt dosage, insert a small screwdriver into the
white indicator knob and move pointer to proper salt
se ing (Figure 10).
Note: To convert the salt se ings from English to metric,
divide by 2.2 (e.g., 12 pounds ³ 2.2 = 5.5 kg of salt).