Specifications
| 10 | ProFlow Eliminator
Removing the Valve
Assembly for Servicing
1. Unplug the power cord.
2. Shut off water supply or put bypass valve(s) into
bypass position.
3. Remove cover and with screwdriver, relieve tank
pressure by pushing open valve No. 7 (rear fl apper)
on control as shown (Figure 11).
4. When used with a globe valve bypass, loosen and
detach the inlet, outlet, brine and drain lines from the
valve. If using the bypass, loosen and remove valve
from bypass as well as loosening and removing the
brine and drain lines.
5. Unscrew valve (counterclockwise) and remove valve
from tank.
6. To replace the control valve, reverse the above
procedure.
Controller for Servicing
1. Unplug the power cord.
2. Remove cover.
3. Align the indicator arrow on the rear of the camsha
with the top of the rear hoop of the top plate (Figure
12).
4. Remove the camsha by carefully pushing the
securing tab, located at the rear of the camsha , away
from the camsha until the tab disengages from the
camsha . Push the back of the camsha down and out
to the inlet side of the valve (Figure 13).
5. Disengage the front of the camsha from the output
gear of the control.
6. Remove the timer locking pin and li the control
straight up and off of the valve.
7. To reinstall the camsha and control, reverse the
above procedures.
Figure 11: Valve assembly
Figure 12: Top-down view of valve
Indicator Arrow
Figure 13: Removing the camsha