Models: SA-Eliminator 48 S-100 SA-Eliminator 70 S-100 SA-Eliminator 90 S-100 S-100 Installation, Opeeration, and Maintenance Manual
MODEL: SA-ELIMINATOR 48 S-100 Water Softener o o Operating Temperature: 34 –120 F Operating Pressure: 25–125 psi Voltage: 110V 60 cycles Rated Service Flow: 12.1 GPM @ 13 psi drop Rated Softening Capacity: 31,200 @ 7.5; 41,900 @ (Grains / Pounds of Salt) 15.2; 47,600 @ 21.2 Max Flow Rate to Drain: 4.3 GPM Amount of High Capacity Resin: 1.5 ft3 Rated Efficiency: 4,170 grains @ 7.
Table of Contents Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Location Selection Water Line Connection Drain Line Connection Brine Line Overflow Line Connection Placing Conditioner into Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Electrical Connection ProFlow 460i Series Control Se ings . . . . . . . . . . . . . . . . . . . . . .
Installation All plumbing and electrical connections must conform to local codes. The most common bypass systems are the Autotrol Series 1265 bypass valve (1) and plumbed-in globe valves (2). Though both are similar in function, the Autotrol Series 1265 bypass offers simplicity and ease of operation. Inspect unit carefully for carrier shortage or shipping damage. Not in Bypass PA S S 4.
the bo om of the loop is level with the drain line connection. This will provide an adequate siphon trap. 5. Where the drain empties into an overhead sewer line, a sink-type trap must be used. IMPORTANT: Never insert drain line into a drain, sewer line or trap. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the conditioner. Note: Standard commercial practices have been expressed here.
Placing Conditioner into Operation A er all previous steps have been completed, the unit is ready to be placed into operation. Follow these steps carefully. 1. Remove control valve cover by first releasing the plastic clip from the back of the cover. Pull back of cover slightly outward and li up. Note: The following steps will require turning the indicator knob ( and ) to various positions. Manually rotate the camsha COUNTERCLOCKWISE only until indicator knob points to desired position.
Pro Flow 460i Series Control Settings ProFlow 460i Control Water-Flow Indicator Hour Time Display PM Indicator Access Door Raised Tab Jumper Spare Jumper Indicator Knob Time-Set Button Timer Locking Pin Transformer Plug Receptable Programming Plug the wall-mount transformer into a functioning electrical outlet that is not controlled by a switch. Plug the transformer into the transformer plug receptacle on the control.
Hardness Setting Move the jumper to the set of pins next to the word HARDNESS (8). Press the black TIME SET bu on until the hardness of the incoming water supply is displayed. The hardness range is from 1 to 99 grains per gallon. To change water hardness stated in parts per million (PPM) to grains per gallon (GPG) use this formula: ppm 17.1 4. Depress the black TIME SET bu on. The numbers will roll from “0” to “15.” Release the switch at the desired number of days for the calendar override.
Model 48 70 90 Capacity Default Se ing Salt Se ing 31,200 gr 48,000 gr 37,400 gr Model 7.5 lbs 48 70 11.5 lbs 90 8.8 lbs Table 1: Default salt se ing, by model Max Flow Pressure Drop @ Rate Max Flow 12.1 gpm 15.5 gpm 18.0 gpm Exchange Media Max Flow to Drain (Regeneration) 13.0 psi 1.5 3 2.5 gpm 15.0 psi 2.3 3 3.5 gpm 2.5 3 4.0 gpm 15.0 psi Table 2: Flow rates and pressure loss Efficiency Ratings Model Tot. Gr. Recovr’d Gr. Recov’rd p/ Salt lb HighEff. Salt Se ing Tot. Gr.
Removing the Valve Assembly for Servicing 1. Unplug the power cord. 2. Shut off water supply or put bypass valve(s) into bypass position. 3. Remove cover and with screwdriver, relieve tank pressure by pushing open valve No. 7 (rear flapper) on control as shown (Figure 11). 4. When used with a globe valve bypass, loosen and detach the inlet, outlet, brine and drain lines from the valve. If using the bypass, loosen and remove valve from bypass as well as loosening and removing the brine and drain lines.
Preventive Maintenance Injector Screen and Injector Inspect and clean brine tank and screen filter on end of brine pickup tube once a year or when sediment appears in the bo om of the brine tank. Clean injector screen and injector once a year: Water Meter Maintenance Note: A water meter is used only with the 460i control. If you are using the 440i control, this section does not pertain to your conditioner. The metering device used with the 460i demand control may require simple maintenance.
Specifications: Control Valve AUV - 268-460i Hydrostatic Test Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 psi (20.69 bar) Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-125 psi (1.38 - 8.62 bar) Standard Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications: Control Valve AUV - 268-460i Injector #1031363 Injector #1031364 "A" in a 268 Valve "B" in a 268 Valve 1.00 0.30 0.20 Total 1.25 0.25 0.75 0.20 Rinse 0.05 0.00 0.50 Brine Draw 0.15 0.75 GPM 0.10 M3/hr Rinse GPM M3/hr 0.15 Total 1.00 0.10 0.50 0.05 0.25 0.00 0.00 Brine Draw 0.25 0.00 20 40 60 400 600 PSI 80 100 120 20 800 1000 1200 1400 1600 1800 bar 40 400 600 1.25 0.20 0.10 0.05 M3/hr Rinse GPM M3/hr 0.25 Total 1.00 0.75 0.05 0.25 0.
Identification of Control Valving Valve Disc Principle of Operation Backwash Drain Valves (7) Refill Valve (5) Cam Inlet Valve (3) Valve Disc Brine Valve (1) Rinse Drain Valve (6) Outlet Valve (4) Bypass Valve (2) Valve Seat Valve Disc Closed Flow Diagrams Service Position Valve Position 1 Closed 2 Closed 3 Open 4 Open 5 Closed 6 Closed 7 Closed | 14 | ProFlow Eliminator Backwash Position Valve Position 1 Closed 2 Open 3 Closed 4 Open 5 Closed 6 Closed 7 Open Valve Disc Open
Brining / Slow-Rinse Position Valve Position 1 Closed 2 Closed 3 Open 4 Open 5 Open 6 Closed 7 Closed Purge Position Valve Position 1 Closed 2 Open 3 Open 4 Closed 5 Closed 6 Open 7 Closed Brine Refine Position Valve Position 1 Closed 2 Closed 3 Open 4 Open 5 Open 6 Closed 7 Closed ProFlow Eliminator | 15 |
Replacement Parts AUV - 1053832 ProFlow: High-Flow Eliminator Series 6 19 14 3 8 12 Parts List Code 1 Part # Description AUV-1053832 Control Valve (Complete) Valve Assembly, w/o Flow Controls (460i) 2a Qty Code 1 8 Camshaft: (all models) 1 1 2b AVP-1035627 Extra Salt Cam (for model 90 only) 3 AVP-1031391 Timer Locking Pin 1 Drain Control Assembly 1 4 5 AVP-1000212 No. 10 (2.5 gpm; 9.5 Lpm) AVP-1000213 No. 12 (3.5 gpm; 13.
Replacement Parts: Distributor Assembly All Models (48, 70, and 90) 2 1 DST-2001: High-Flow Upper Distributor 4,5 3 10 9 7 13 14 11 6 15 12 8 Code #6: DST-1021-E: High-Flow Distributor SA-Eliminator 48, 70, and 90 (S-100) Code #4: Eliminator Cap Number JKT-1220 Code JKT-1165 JKT-1095 Eliminator 48 JKT-1115 Eliminator 70 JKT-1180 Eliminator 90 JKT-1233 Code #5: Eliminator Jacket Numbers Part # Description 48 Qty 70 Qty 90 Qty 1 AUV-1053832 268/460i Meter 1 1 1 2 AVP-1000062 I-
460i Control BP-A-1040930 B Y PA S S B Y PA S S Code #2 Code #3: Bypass Code Part # 2 Description Qty Bypass Kit 460i Control 1 BP-A-1001606 3/4" Copper Tail Kit 3 AVP-1040930 1265 Bypass (see table at right) 1 BP-A-1001670 1" Copper Tail Kit * AVP-1000811 Transformer (460i): 1 BP-A-1001210 1 1/4" Copper Tail Kit * AVP-1000907 Transformer Extension Cord 15 feet (4.
Troubleshooting The technology upon which the control valve is based is well established and proven in service over many years. However, should a problem or question arise regarding the operation of the system, the control can very easily be serviced. For parts mentioned, refer to exploded views in the Replacement Parts section of this manual. IMPORTANT: Service procedures that require the water pressure to be removed from the system are marked with a “§ ” a er the possible cause.
460i Control Troubleshooting Problem Possible Cause Solution Clock does not display time of day. Transformer cord unplugged. Connect power. No electric power at outlet. Repair outlet or use working outlet. Clock does not display correct time of day. Defective transformer. Replace transformer. Defective circuit board. Replace timer. Outlet operated by switch. Use outlet not controlled by switch. Incorrect voltage or frequency (Hz). Replace timer with one of correct voltage and frequency (Hz).
460i Control Troubleshooting (con't) Problem Possible Cause Solution Control will not regenerate automatically or when button is pressed. Electric cord unplugged. Connect power. No electric power at outlet. Repair outlet or use working outlet. Defective motor. Replace timer. Broken gear. Replace timer. Control will not regenerate automatically but will regenerate when button is pressed. Run out of soft water between regenerations. Binding in gear train. Replace timer. Defective switch.
Disinfection of Water Conditioners 1. Dosage a. Polystyrene resin: 1.2 fluid ounces per cubic foot. b. Non-resinous exchangers: 0.8 fluid ounce per cubic foot. The materials of construction of the modern water conditioner will not support bacterial growth, nor will these materials contaminate a water supply.
Manufacturer’s Warranty R&M Water Group A Division of Water Technologies Inc. To the original purchaser, the valve body, mineral container, cation resin, and salt tank carry an unconditional, non-prorated lifetime guarantee, which may be replaced F.O.B. R&M Service Center. This water conditioner, manufactured by R&M Water Group, is unconditionally guaranteed as to workmanship and materials at the original installation site for a period of five years from the date of original purchase.