Specification Sheet

Product Features
Lever control with variable flow
Heavy-duty solid no lead brass hose adapter
Pipe and rod are galvanized to prevent rust
Head and lever can be padlocked when not in use to prevent unauthorized use
Metal gland and packing nut included
Drains below the frost line once hydrant is shut off
Inlet: 3/4” NPT in no lead brass casting
Outlet: 3/4” no lead brass hose thread
Graphite packing
Steel and molded rubber plunger made of self-lubricating material
1” galvanized pipe
Overall length is 28” plus bury depth (bury depth is stenciled on pipe)
PFXEM Series
Frost Proof Yard Hydrants
© 2015 Ferguson Enterprises, Inc. All Rights Reserved
Distributed Exclusively by Ferguson and Wolseley Canada
12483 06/15
PFXEM SERIES
PFXEM7501
PFXEM7502
PFXEM7503
PFXEM7504
PFXEM7505
PFXEM7506
PFXEM75015
DESCRIPTION
OVERALL LENGTH
(INCHES)
1 FT BURY FREEZELESS YARD HYDRANT
2 FT BURY FREEZELESS YARD HYDRANT
3 FT BURY FREEZELESS YARD HYDRANT
4 FT BURY FREEZELESS YARD HYDRANT
5 FT BURY FREEZELESS YARD HYDRANT
6 FT BURY FREEZELESS YARD HYDRANT
1-1/2FT BURY FREEZELESS YARD HYDRANT
39.5
51.5
63.5
75.5
87.5
99.5
45.5
*PFXEM7508
*PFXEM7510
8 FT BURY FREEZELESS YARD HYDRANT
10 FT BURY FREEZELESS YARD HYDRANT
123.5
147.5
20 PSI
30 PSI
40 PSI
60 PSI
80 PSI
100 PSI
0 5 10 15 20 25 30 35 40 45 50
GALLONS PER MINUTE ( GPM )
NOTE: Most common 1/2 hp submersible pumps output is 10 GPM.
WATER
SYSTEM
PRESSURE
15.4 GPM @ 20 PSI
18 GPM @ 30 PSI
22 GPM @ 40 PSI
27 GPM @ 60 PSI
32 GPM @ 80 PSI
36 GPM @ 100 PSI
Warranty and Codes
This PROFLO product carries a 1-year limited warranty.
Made in U.S.A.
Parts Available
PFEM7500RK
Repair Kit for PFEM7500 Series Yard Hydrant includes one each of the following:
- Draw straps (pair)
- Pivot connector and nuts
- Packing nut
A - Lever Control
B - Draw Straps
C - Operating Rod
D - Heavy-Duty Solid
No Lead Brass Hose Adapter
E - Heavy Cast Iron Head
F - Pivot Connector with
Stainless Steel Bolt
G - Packing Gland
H - Galvanized Pipe
I - Long-life One Piece Plunger
J -
Double Bypass No Lead Valve Body
K -
Locking Eye
A
B
C
F
K
H
J
I
D
E
G
Ground Level
Hydrant stands about 28"
above ground level.
Hydrant bury depth
or depth water lines
are buried underground.
*For Canada only
Low-Lead Compliant
- Valve stem packing
- Plunger
PFXEMHDL - Lever control (A)

Summary of content (1 pages)