Specification Sheet

Product Features
•
Lever control with variable flow
• Heavy-duty solid no lead brass hose adapter
• Pipe and rod are galvanized to prevent rust
• Head and lever can be padlocked when not in use to prevent unauthorized use
• Metal gland and packing nut included
• Drains below the frost line once hydrant is shut off
• Inlet: 3/4” NPT in no lead brass casting
• Outlet: 3/4” no lead brass hose thread
• Graphite packing
• Steel and molded rubber plunger made of self-lubricating material
• 1” galvanized pipe
• Overall length is 28” plus bury depth (bury depth is stenciled on pipe)
PFXEM Series
Frost Proof Yard Hydrants
© 2015 Ferguson Enterprises, Inc. All Rights Reserved
Distributed Exclusively by Ferguson and Wolseley Canada
12483 06/15
PFXEM SERIES
PFXEM7501
PFXEM7502
PFXEM7503
PFXEM7504
PFXEM7505
PFXEM7506
PFXEM75015
DESCRIPTION
OVERALL LENGTH
(INCHES)
1 FT BURY FREEZELESS YARD HYDRANT
2 FT BURY FREEZELESS YARD HYDRANT
3 FT BURY FREEZELESS YARD HYDRANT
4 FT BURY FREEZELESS YARD HYDRANT
5 FT BURY FREEZELESS YARD HYDRANT
6 FT BURY FREEZELESS YARD HYDRANT
1-1/2FT BURY FREEZELESS YARD HYDRANT
39.5
51.5
63.5
75.5
87.5
99.5
45.5
*PFXEM7508
*PFXEM7510
8 FT BURY FREEZELESS YARD HYDRANT
10 FT BURY FREEZELESS YARD HYDRANT
123.5
147.5
20 PSI
30 PSI
40 PSI
60 PSI
80 PSI
100 PSI
0 5 10 15 20 25 30 35 40 45 50
GALLONS PER MINUTE ( GPM )
NOTE: Most common 1/2 hp submersible pumps output is 10 GPM.
WATER
SYSTEM
PRESSURE
15.4 GPM @ 20 PSI
18 GPM @ 30 PSI
22 GPM @ 40 PSI
27 GPM @ 60 PSI
32 GPM @ 80 PSI
36 GPM @ 100 PSI
Warranty and Codes
This PROFLO product carries a 1-year limited warranty.
Made in U.S.A.
Parts Available
PFEM7500RK
Repair Kit for PFEM7500 Series Yard Hydrant includes one each of the following:
- Draw straps (pair)
- Pivot connector and nuts
- Packing nut
A - Lever Control
B - Draw Straps
C - Operating Rod
D - Heavy-Duty Solid
No Lead Brass Hose Adapter
E - Heavy Cast Iron Head
F - Pivot Connector with
Stainless Steel Bolt
G - Packing Gland
H - Galvanized Pipe
I - Long-life One Piece Plunger
J -
Double Bypass No Lead Valve Body
K -
Locking Eye
A
B
C
F
K
H
J
I
D
E
G
Ground Level
Hydrant stands about 28"
above ground level.
Hydrant bury depth
or depth water lines
are buried underground.
*For Canada only
Low-Lead Compliant
- Valve stem packing
- Plunger
PFXEMHDL - Lever control (A)