Product Features
· Rated 6 DFU’s for venting DWV 2" and smaller
· Unique technology opens at -0.01 psi and seals at 0 psi and above
· Screening on air inlets to guard the seal
· Protective rubber sleeve provides grip for installation and keeps valve
free from debris
· 100% functionally tested at 1/4" H20 and 30" H20 ensuring trouble
free performance
Model Numbers
PFA AV6 20 BR/8 STK AAV 1.5 PVC ADPT
PFA AV6A 20 BR/8 STK AAV W 1.5 ABS ADPT
General Specifications
An air admittance valve shall be acceptable as a vent termination for
any individual vent, common vent, circuit vent, loop vent, island fixture
vent, vent stack or stack vent that is provided to prevent siphonage of
a fixture trap.
An AAV is used as an alternative to secondary venting through the
roof open to atmosphere and to prevent sewer gases from escaping
into a building. Additionally, it is a one-way valve designed to allow
air to enter the plumbing drainage system when negative pressure
develops in a piping system without the use of a vent extended to
open air. The device shall close by gravity and seal the vent terminal
at zero differential pressure (no flow conditions) and under positive
internal pressures.
Product Location Specifications
· Should be located a minimum of 4" above the weir of fixture trap for
single fixture and branch venting and 6" above flood level of highest
fixture for stack venting
· Each valve should be installed in an accessible location
Performance Standards
· ASSE 1050 & 1051
· ICC ESR – 1664
· NSF Standard 14
· IAPMO – classified mark
· ASTM D 2665/D 2661
Code Approvals
· International Plumbing Code (IPC) 2003
· International Residential Code (IRC) 2003
PFAAV6
Air Admittance Valves
¨
®
DWV
Warranty
This PROFLO product carries a standard 1-year limited warranty.