PC190 Control Box 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL R112 R113 R106 R110 R111 R107 R108 R103 R105 R102 J1 R104 Transformer J2 MOV1 T4 + - DB1 SW3 UP + SW4 SET SW5 - DOWN SW1 F1 RF-LEARN - + NC NO K5 CO P190-PCB1 0121-377-A1 Q17
Index 1). Control Box Installation 2 2). Wiring Connection 2 2.1 Motor Connection 3 2.1.1 Motor Only 3 2.1.2 Motor With Limit Switch 3 2.1.3 Motor With Hall Sensor 3 2.2 Wifi Device 4 2.2.1 Back-up Batteries 4 2.3 Accessories 5 2.3.1 Photocells 5 3). Get Started 6 3.1 Step 1: Remote Memorizing 6 3.1.1 Memorizing 6 3.1.2 Remote learning without Control board 7 3.1.3 Deleting memory of single command 7 3.1.4 Deleting all memory of all remotes 7 3.
1). Control Box Installation 1. Decide the installation position of control box first, it is suggested to be installed near the gate and should be protected from possible damage. Be aware of the motor cable length before deciding the installation position. 2. Remove the cover by unscrewing the four screws on the cover. See Figure A. 3. Use a screwdriver to puncture the holes beneath the bottom of the control box. See Figure B. 4. Secure it on the wall Figure C. Figure A Figure B Figure C 2).
PC190 40121-37 J2 K1 T4 DB1 +K2 - MOV1 K3 2.1 Motor Connection 2.1.
2.2 Wifi Device Functions of Buttons and Terminals L E D D i s p l a y P button: WIFI paring: Press 1 sec Default setting: Press 3 sec R button: Terminals Press to restart • LED description: Blue: LED will be flashing during WIFI pairing, and be ON when completed. Green: LED will be flashing if WB-001 receives signal from APP. If your home WIFI disconnects, the green light will continuously flash, and it will be off until WIFI is connected again. Red: System failure or wrong PIN. 2.2.
2.3 Accessories 2.3.1 Photocells The safety photocells are security devices for control automatic gates. Consist of one transmitter and one receiver based in waterproof covers; it is triggered while breaking the path of the beams.
3). Get Started Note: (A) Transmitter memorizing must be done first before system learning. (B) CHECKING THE Gate MOVEMENTS 1) Release the gearmotor with the release key and move the gate to the middle so that it is free to move in both opening and closing directions; then lock the gearmotor. 2) Perform the gate opening and closing several times and make sure the gates touches the limit switch at least 2~3 cm before the mechanical stop. 3.1 Step 1: Remote Memorizing 3.1.1 Memorizing 1.
3.1.2 Remote learning without Control board: 2 1 5 A B A B B 4 A 3 2 1 Press the button again 3 TIMES AC INPUT 3.1.3 Deleting memory of single command: Single deletion stage is needed for each memorized button. 1. Press and hold down RF-LEARN button (Figure 3) on the control board for 5 seconds. 2. Wait until the LED display shows “DKY”, then, within three seconds: 3. Press the button of the remote to be deleted. If the remote has been deleted, the LED display will flash quickly five times.
3.2 Step 2: System Learning Step1: Press and Hold the Press SET button for 3s, When LED shows “LEA” then release SET, then the motor runs the system learning procedure automatically, once learning completed shows “D-G” or “S-G” (No remote required) Note: Please check the parameter setting of “FI”(Dual/Single) before going into system learning. 14 Restore system default setting Press and Hold the UP + SET + DOWN button for 5s and panel restores back to default setting LED1 LED2 LED3 Note: 1.
Lit- Lat+ Lat- M1+ M1- M2+ M2- 5V S1 S2 GND Lmt1 Lmt2 GND Lmt3 Lmt4 GND DKey SKey GND Ph1 PhVcc GND Ph2 PhVcc 1 Lit+ 6 4). Gate Operation Logic 5 4 3 (A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when the transmitter/push button/key selector is reactivated. (B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when the transmitter/push button/key selector is reactivated.
13 12 11 10 9 8 7 6 5 4 3 2 1 14 LED1 LED2 LED2 LED3 LED3 UP 13 12 11 10 9 8 3 7 6 5 4 3 2 1 14 13 12 11 10 3 UP 14 4 LED3 LED1 4 5 7.1 Parameter Learning LED2 5 6 LED1 6 7). Parameter Modification UP 2 2 1 1 SET SET Push 14 DOWN 13 12 11 10 AC INPUT 9 8 7 6 5 4 3 2 1 14 13 12 AC INPUT DOWN SET Push 1 3 LED1 5 LED2 LED2 4 Press “UP” or “DOWN” to change setting item from F1 to FJ .
LED Display F8 Definition Parameter Time Gap b/w Two Gates F8-0 0 sec (Closing) F8-1 2 sec Table Description 1. The factory setting is "F8-1". F8-2 5 sec F8-3 10 sec F8-4 15 sec F8-5 20 sec F8-6 25 sec F8-7 35 sec F8-8 45 sec F8-9 55 sec F9 Auto-closing F9-0 Function OFF 1. Auto-close mode activates when the gates move to F9-1 3 sec the end position or stopped manually.
The value can be adjusted by pressing button UP and DOWN. The maximum value is 50(5.0A) and the minimum value is 05(0.5A). LED display example: Indicate 1.0 ampere: all of the recorded values will increase 1 ampere as over current value. Indicate 2.8 ampere: all of the recorded values will increase 2.8 ampere as over current value. Indicate 0.6 ampere: all of the recorded values will increase 0.6 ampere as over current value. 7.
8) .Trouble Shooting Issue: Solution: Parts to look at: No power on the board. - Power to the transformer is on and the connector block from the AC power lead to the transformer and to the control board is wired correctly. - At the control board check the transformer white connector blocks are correctly plugged into board and the battery connector if equipped. - Check fuses are both working. * 15amp for stand-alone transformer. - Check there is 24vac into and out of the Control box fuse.
9). Technical Specification Main power supply Back-up battery Receiver board Installation Operating Temperature Dimension 14 230Vac/110Vac, 50Hz/60Hz 2pcs of batteries for emergency operation, 2.2A each 433.