User guide
9
(2) Check that FP has instllation fastners. Insert the FP from the front.
(3) The following figures show the eight(8) fastener insertion slot locations. Insert each
fastener's hook into the slot and tighten it with a screwdriver.
• To avoid an electric shock, when connecting the FP’s power cord terminals to the
power terminal block, confirm that the FP’s power supply is completely turned OFF,
via a breaker, or similar unit.
• To avoid the dangers of fire, electric hazards and equipment damage, be sure to use
only the specified voltage when operating the FP.
• Since there is no power switch on the FP unit, be sure to attach a breaker-type switch
to its power cord.
Electrical Specification
• Installation gasket must be used even though it is not necessary for
its environment. For installation, refer to the FP-3710T series User
Manual.
• Tightening the screws with too much force can damage the FP unit’s
case.
• The necessary torque is 0.5N•m.
6 Wiring
Item Specification
Power Supply
Input Voltage AC100 ~ 240V
Rated Voltage AC85V ~ AC264V
Rated Frequency 50 / 60HZ
Allowable Frequency Range 40Hz - 72Hz
Allowable Voltage Drop 1 cycle (Max.)
Current Consumption
AC100V 1.1A or less (TYP 0.75A)
AC240V 0.7A or less (TYP 0.44A)
In-Rush Current 60A (Max.)
Left side
Bottom Right side
Insertion
Slots
Panel
Installation
fastener
Top
FP
Hook