Manual
9
(2) Check that FP has installation fasteners. Insert the FP from the front.
(3) The following figures show the twelve (12) fastener insertion slot locations.
Insert each fastener's hook into the slot and tighten it with a screwdriver.
• To avoid an electric shock, when connecting the FP’s power cord terminals to the
power terminal block, confirm that the FP’s power supply is completely turned
OFF, via a breaker, or similar unit.
• To avoid the dangers of fire, electric hazards and equipment damage, be sure to
use only the specified voltage when operating the FP.
• Since there is no power switch on the FP unit, be sure to attach a breaker-type
switch to its power cord.
• Installation gasket must be used even though it is not
necessary for its environment. For installation, refer to the FP-
3710K Series User Manual.
• Check that the installation panel or cabinet's surface is flat, in
good condition and has no jagged edges. Also, if desired,
metal reinforcing strips can be attached to the inside of the
panel, near the Panel Cut, to increase the panel's strength.
• Tightening the screws with too much force can damage the
FP unit’s case.
• The necessary torque is
0.8
N•m.
6 Wiring
FP
Unit: mm [in]
441.5 [17.38 ]
+1
- 0
+0.04
- 0
313.5
+1
- 0
[12.34 ]
+0.04
- 0
r ≤ 3[0.12]
FP
Panel
Panel thickness
1.6[0.06] to 10[0.39]
Left side
Bottom
Right side
Insertion
Slots
Panel
Installation
fastener
Top
FP
Hook