Use the following wiring for FP. Those are Phoenix Contact products.
Connecting the Power Cord
When connecting the AC type power cord, be sure to follow the procedures given
below.
(1) Confirm that the power cord is unplugged from the power supply.
(2) Push the Opening button by a small and flat screw driver to open the desired pin
hole.
(3) Insert each pin terminal into its each hole. Release the Opening button to clamp
the pin place.
(4) After inserting all three pins, insert the Power Plug into the Power Connector at
FP. Fix the plug with two(2) minus screws.
USB Cable Clamp Attachment Procedure
Installation to USB cable
(1) Connect the USB cable to the connector.
(2) Insert the cable clamp into the cable clamp holder as shown in the following
figure, and tighten the clamp until the cable is secured in place.
• Kind of power cord is FKC 2,5/3-STF-5,08 which are Phoenix
Contact products.
Recommended Drivers SZS 0.6X3.5 (1205053)
Recommended stick end
terminal
AI 0.75-10GY(3201288) AI 1-10RD(3200182)
AI 1.5-10BK(3200195) AI 2.5-12BU(3200962)
Crimp tool for recommended
stick end terminal
CRIMPFOX ZA 3 (1201882)
• The torque required to tighten these screws is 0.5N•m to
0.6N•m.
• To prevent the possibility of a terminal short, use a pin terminal
that has an insulating sleeve.
7 Using the USB Cable Clamp
AC power supply cord
Opening Button
L
N
FG
USB cable clamp
USB Cable
Stopper
USB cable clamp holder