Please pay special attention to the following instructions when connecting the
power cord terminals to the FP unit.
If the power supply voltage exceeds the FP unit’s specified range, connect a
voltage transformer.
Between the line and the ground, be sure to use a low noise power supply. If
there is still an excessive amount of noise, connect a noise reducing
transformer.
Input and Output signal lines must be separated from the power control cables
for operational circuits.
The FP unit’s power supply cord should not be bundled with or kept close to
main circuit lines (high voltage, high current), or input/output signal lines.
Connect a surge absorber to handle power surges.
To reduce noise, make the power cord as short as possible.
The temperature rating of field installed conductors: 75 ºC only (FP3500-T41-
24V/FP3600-T41-24V only).
When attaching a wire to the FP unit’s rear face FG terminal, (on the AC
Connector), be sure to create an exclusive ground.
(Use a grounding resistance of 100, a wire of 2mm
2
or thicker, or your country’s
applicable standard.)
All FP Input and Output signal lines must be separated from all operating
circuit (power) cables.
If this is not possible, use a shielded cable and ground the shield.
OSD Functions
You can operate the FP screen menus via the touch panel, and even if FP is
operating, adjust screen image display to a minute level. The feature is called
OSD (On Screen Display). The items that can be set with OSD and the functions
are shown.
8 Power Supply Cautions
9 Grounding Caution
10 Input/Output Signal Line Cautions
11 Calibration of OSD Display Position
Example of OSD screen
"Ver.*.**" indicates the version of the OSD.