Caution Be sure to read the “Warning/Caution Information” on the attached sheet before using the product. Package Contents FP unit (1) Installation Guide (1) (this manual) Warning/Caution Information (1) Installation Gasket (1) (attached to the FP unit) Installation Fasteners (4/set, 1set) USB Cable Clamp (2) DC Power Connector (1) (attached to the FP unit) (Only supplied with FP3500-T41-24V/FP3600-T41-24V) This unit has been carefully packed, with special attention to quality.
UL/c-UL/CSA Application Notes Qualified Product (UL File No.E220851, CSA File No.219866) The following units are UL/c-UL/CSA listed products. (UL File No.E220851, CSA File No.219866) Model Type FP3500-T41-24V FP3600-T41-24V UL/c-UL/CSA Registration Model No. 3580403-02 3580404-02 These products conform to the following standards: • UL508 Industrial Control Equipment • CSA-C22.2, No.142-M1987 Process Control Equipment Qualified Product (UL File No.
CE Marking Notes The FP3650-T41 is a CE marked product complying with both the EMC Directive and low voltage directive. It complies with EN55011 Class A, EN61000-6-2 and EN60950-1 First Edition. The FP3500-T41-24V and FP3600-T41-24V are CE marked products complying with the EMC Directive. They comply with EN55011 Class A, EN61000-6-2. * For detailed CE marking information, please contact your local FP distributor.
1 Part Names This model is FP3600-T11. Front View I A,B Rear View C D E J Bottom View F G H A: TFT Color LCD Acts as a display monitor for your host. B: Touch Panel Allows you to switch screens or write data to the host. C: Input Terminal Block (FP3500-T11/ FP3600-T11/FP3650-T41) or Power Connector (Socket) (FP3500-T41-24V/ FP3600-T41-24V) Provides the input and ground terminals for a power cable. D: Setting Switch By opening the cover, the Dip switches and slide switch are seen.
2 Dimensions Unit: mm [in] Top View 301[11.85] 58[2.28] Front View 227[8.94] 243[9.57] 243[9.57] Front View (FP3500-T11/FP3500-T41-24V) 3 8[0.31] 317[12.48] 317[12.48] Side View (FP3600-T11 /FP3600-T41-24V /FP3650-T41) Dip Switches and Slide Switch The Dip Switches and Slide Switch are located in the bottom of the FP unit. Only the settings when the power supply is turned on is effective to the Dip Switches and the Slide Switch.
4 Interfaces Analog RGB Interface Input signal type Input signal characteristic Setting by OSD (On Screen Display) Analog RGB Image signal : analog RGB Synchronous signal :TTL level, negative true or positive true Scanning type : non-interlace •CONTRAST •BRIGHTNESS •H-POSITION •V-POSITION •H-size •PHASE •DIMMER(BACKLIGHT) •SHARPNESS •ALL RESET (DEFAULT) Display Area (FP3500-T11/FP3500-T41-24V) Size *1 640×350 640×400 640×400 640×480 720×350*1*2 720×400*1 H Sync. (kHz) 31.469 31.469 24.827 31.
(FP3600-T11/FP3600-T41-24V) Size 640×350*1 640×400 640×400 640×480 640×480 640×480 720×350*1*2 720×400*2 800×600 800×600 H Sync. (kHz) 31.469 31.469 24.827 31.469 35.000 37.861 31.469 31.469 35.156 37.879 V Sync. Dot Clock Screen Resolution Expansion Display (Hz) (MHz) (H: Horizontal) (V: Vertical) Resolution 70.000 25.175 800×525 ×1.25 (H) 70.000 25.175 800×600 ×1.5 (V) 56.420 21.053 800×600 59.992 25.175 ×1.25 (H) 66.670 30.240 800×600 ×1.25 (V) 72.810 31.500 70.000 28.320 800×525 ×1.1 (H) ×1.5 (V) 70.
Pin Assignments and Signal Names for Analog RGB Pin No. Signal Name Pin No. Signal Name Pin No. Signal Name 1 Analog R 6 Return R 11 Reserved 2 Analog G 7 Return G 12 DDC DATA 3 Analog B 8 Return B 13 H. SYNC 4 Reserved 9 Reserved 14 V. SYNC Pin Location 15 11 5 1 5 Digital grounding 10 Digital grounding 15 DDC CLOCK Connector ..................... Mini Dsub 15 pin male Connector set screw ..... Inch type (#4-40UNC) Cable.............................
(FP3600-T11/FP3600-T41-24): Size 640×400 640×400 640×480 640×480 640×480 H Sync. (kHz) 31.469 24.827 31.469 35.000 37.861 720×400*1 31.469 800×600 800×600 35.156 37.879 V Sync. Dot Clock Screen Resolution Expansion Display (Hz) (MHz) (H: Horizontal) (V: Vertical) Resolution 70.000 25.175 ×1.25 (H) ×1.5 (V) 56.420 21.053 59.992 25.175 ×1.25 (H) 66.670 30.240 ×1.25 (V) 800×600 72.810 31.500 ×1.1 (H) 70.000 28.320 ×1.5 (V) 56.250 36.000 ×1.0 60.317 40.000 *1.
Pin Assignments and Signal Names for DVI-D 4 5 12 13 20 21 6 DDC Clock 14 NC 22 7 8 DDC Data NC 15 16 GND Hot Plug Detect 23 24 3 11 19 Signal Name Pin Location TMDS DATA0TMDS DATA0+ TMDS DATA0 SHIELD 17 NC NC TMDS CLOCK 24 SHIELD TMDS CLOCK+ TMDS CLOCK- 8 17 18 16 Pin TMDS DATA1TMDS DATA1+ TMDS DATA1 SHIELD NC NC 24 Signal Name 9 10 1 Pin TMDS DATA2TMDS DATA2+ TMDS DATA2 SHIELD NC NC 9 Signal Name 1 2 17 Pin 1 8 Connector .....................
Serial Interface RS-232C Serial Interface Baud rate : 9600 bps Data length : 8 bits Parity : None Stop bit :1 Flow Control: None Pin Assignments and Signal Names for Serial Interface Pin No.
5 Installation (1) According to the Panel Cut size, make installation holes on the panel. Also, determine the panel thickness according to the panel thickness range with due consideration of panel strength. Panel FP Panel thickness 1.6[0.06] to 10[0.39] 0 227.5 +10 301.5 +10 [11.87 +0.04 ] r ≤ 3[0.12] 0 [8.96 +0.04 ] Unit: mm [in] FP (2) Check that FP has installation fasteners. Insert the FP from the front. • Installation gasket must be used even though it is not necessary for its environment.
6 Wiring • To avoid an electric shock, when connecting the FP’s power cord terminals to the power terminal block, confirm that the FP’s power supply is completely turned OFF, via a breaker, or similar unit. • To avoid the dangers of fire, electric hazards and equipment damage, be sure to use only the specified voltage when operating the FP. • Since there is no power switch on the FP unit, be sure to attach a breaker-type switch to its power cord.
FP3500-T11/FP3600-T11/FP3650-T41 (Type AC) Power Cable Connecting Power Cord Recommended Ring terminal*1 *1. AC cable Double insulation wire 1.25~2.0 mm2 (16-14AWG) V2-MS3 compatible (J.S.T. Mfg. Co.,Ltd). Over ø3.2 mm[0.13 in.] Grounding Wire Under 6.0 mm [0.24 in.] Under 7.0 mm [0.28 in.] 1.25~2.0 mm2 (16-14AWG) V2-P4 compatible (J.S.T. Mfg. Co.,Ltd). Over ø4.3 mm[0.17 in.
FP3500-T41-24V/FP3600-T41-24V (Type DC) Power Cable specification Use copper conductors only. 0.75~2.5mm2 (18-12 AWG) Single or Stranded wire*1 Cable thickness Core wire condition 7mm[0.28inch] Core wire length *1. In case of using a strand wire, inappropriate twisting of the core wire may cause short circuit between each wire, or between wire and the abutting electrode contact.
Power cable connecting (1) Make sure that the power cable has no power distribution. (2) Remove the power connector from the unit. (3) There are three screws located in the center of the connecter. Make them loosen. (4) Peel some of the outside of shield part, twist core wires, and insert the wire into each cable joint. (5) Fix all of them with screws. + - FG • Use a minus driver when fixing terminal screws. The necessary torque is 0.5~0.6N•m [ 5~7 lb•in ]. • Cable joints are not allowed to solder.
8 Power Supply Cautions Please pay special attention to the following instructions when connecting the power cord terminals to the FP unit. • If the power supply voltage exceeds the FP unit’s specified range, connect a voltage transformer. • Between the line and the ground, be sure to use a low noise power supply. If there is still an excessive amount of noise, connect a noise reducing transformer. • Input and Output signal lines must be separated from the power control cables for operational circuits.
Item Function Color Settings Adjusts the contrast and the brightness. Screen Settings Adjusts the display position of the screen. Custom Display Adjusts Sharpness and the backlight brightness. System Settings Changes settings such as activating the click sound. All Reset Resets the current OSD value to the default value. Input Source Switches Analog RGB and DVI-D. Auto Adjust Auto Gain Automatically adjusts the display position of the screen.
• In the OSD, pressing the button applies the set value and enables the setting. The set value won’t be canceled unless the power is turned OFF or the value is reset. If the power is turned OFF without saving the set value, that data will disappear. The last saved data will be read into the system when the FP starts. To enable the changed value, be sure to press the button.
System Settings Adjustment button Selection of the change item Enables/disables the click sound. With this Click Tone parameter, the sound level can also be adjusted. (Default value: OFF ) 720x400 Mode When an input data resolution of 720 x 400 is used in the VGA text mode, set this parameter to ON. For other resolutions, set this parameter to OFF. (Default: ON) Auto off Disp Enables/disables the screen display Auto OFF function and sets the time when the Auto OFF function is enabled.
All Reset Resets all the settings and then returns to the top menu. Cancels the setting and then returns to the top menu. Input Source Switches Analog RGB and DVI-D, and quits the OSD. Cancels the setting and then returns to the top menu. Auto Adjust (Analog RGB only) Applies the setting and then returns to the top menu. Cancels the setting and then returns to the top menu. • Be sure to perform the auto adjust while things except that black are shown on sides of the display.