(3) The following figures show the eight (8) fastener insertion slot locations.
Insert each fastener's hook into the slot and tighten it with a screwdriver.
• To avoid an electric shock, when connecting the FP’s power cord terminals to
the power terminal block, confirm that the FP’s power supply is completely
turned OFF, via a breaker, or similar unit.
• To avoid the dangers of fire, electric hazards and equipment damage, be sure
to use only the specified voltage when operating the FP.
• Since there is no power switch on the FP unit, be sure to attach a breaker-type
switch to its power cord.
Electrical Specification
• Tightening the screws with too much force can damage the
FP unit’s case.
• The necessary torque is 0.5 N•m (4.4 lb-in).
Wiring
Item
Specification
DC TYPE AC TYPE
Power Supply
Rated Voltage DC24V AC100 to 240V
Allowable Voltage DC19.2 to 28.8V AC85 to 264V
Rated Frequency - 50 / 60HZ
Allowable Frequency Range - 40 - 72Hz
Allowable Voltage Drop 5ms or less
1 cycle (Max.)
(Voltage drop
interval must be 1s or more.)
Current Consumption 40W or less
AC100V 1.1A or less
(TYP0.75A)
AC240V 0.7A or less
(TYP0.44A)
In-Rush Current 30A or less 60A or less
Voltage Endurance
AC1000V 20mA for 1 minute
(between charging and FG
terminals)
AC1500V 20mA for 1 minute
(between charging and FG
terminals)
Insulation Resistance
DC500V 10MΩ
or more
(between charging and FG
terminals)
DC500V 10MΩ
or more
(between charging and FG
terminals)
Left side
Bottom
Right side
Insertion
Slots
Panel
Installation
fastener
Top
FP
Hook