Serial Interface
Pin Assignments and Signal Names for Serial Interface
*1
The CD, DTR, and DSR are connected together inside of the FP.
Connector ..................... Dsub 9 pin female
Connector set screw ..... Inch type (4-40UNC)
Cable............................. SIO cable for FP manufactured by Pro-face.
(FP61V-IS00-O)
Concerning Signal Names
Signal names used for the serial interface on FP units are designed to match the
pin order used on most PC serial interfaces, so that a straight cable can be used
to connect the two. Therefore, connect each pin’s signal to the same signal name
on the PC side. For example, pin #2 ‘RD’ should be connected to the ‘RD’ input
terminal on the PC’s connector.
Refer to the FP3000 Series User Manual’s section “Cable Diagrams” for each
signal’s direction.
• If a cable other than the specified DVI-D cable is used, product
performance cannot be guaranteed due to the possibility of noise
interfering with the FP unit’s operation.
• Only when the FP-3710T series is connected with PS-2000B or
PL-3000B (Revision B or more), FP-DV01-100 can be used.
• Please turn on PS-2000B's internal dipswitch 4 when you use
FP-DV01-100 with PS-2000B. (The resolution that can be
displayed is 1024 x 768 only (XGA). )
Please turn off dipswitch 4 when you use FP-DV01-50.
• Please set PL-3000B’s internal dipswitch 5 to z sign side when
you use FP-DV01-100 with PL-3000B.
We will recommend the resolution of PL-3000B to change to
the maximum display resolution of FP additionally.
Please set it on the opposite side of z sign when you use FP-
DV01-50.
RS-232C Serial Interface
Baud rate : 9600 bps
Data length : 8 bits
Parity : None
Stop bit : 1
Flow Control: None
Pin No. Signal Name Condition Pin Location
1 CD Carrier Detect
*1
2 RD Receive Data (FP->Host)
3 SD Send Data (FP<-Host)
4 DTR Data Terminal Ready
*1
5 GND Ground
6 DSR Data Set Ready
*1
7 RS Request to Send (FP<-Host)
8 CS Clear to Send (FP->Host)
9 NC (Used internally)