User Manual
10
Environmental Specification
1. Wiring the DC type power supply
cable
Power Cord Specifications
Use copper conductors only.
Wiring
When connecting the power cord, use the
following items when performing wiring.
(Items are made by Phoenix Contact.)
• Accompanying DC type power
supply connector is CA7-DCCNL-
01 from Pro-face or GFKC2,5/3-
STF-7,62 is manufactured by
Phoenix Contact.
Connecting the Power Cord
(1) Confirm that the power is not sup-
plied to the FP unit.
(2) Push the Opening button with a
small and flat screw driver to open
the desired pin hole.
(3) Insert each pin terminal into its each
hole. Release the Opening button to
clamp the pin in place.
(4) After inserting all three pins, insert
the Power Plug into the Power Con-
nector at FP. Fix the plug with two
(2) minus screws.
• The torque required to tighten these
screws is 0.5 to 0.6 N•m (4.4 to 5.3
lb-in).
• To prevent the possibility of a termi-
nal short, use a pin terminal that has
an insulating sleeve.
Item Specification
Surrounding Air
Temperature
0 to 50ºC (The panel should not incline more than 30º)
Storage Temperature -20 to +60ºC
Ambient Humidity
10 to 90%RH
(No condensation, Wet bulb temperature: 39ºC max.)
Storage Humidity
Air Purity (Dust) 0.1mg/m
3
(Max.) (No electrically conductive dust is allowed)
Pollution Degree For use in Pollution Degree 2 environment
Power Cord
Diameter
0.75 to 2.5mm
2
(18 to 12 AWG)
Conductor
Type
Simple or Stranded
Wire
*1
*1
If the Conductor’s end (individual) wires are
not twisted correctly, the end wires may either
short against each other, or against an elec-
trode.
Conductor
Length
Recommended
Driver
SZS 0.6x3.5 (1205053)
Recommended
Pin Terminals
AI 0.75-10GY (3201288)
AI 1-10RD (3200182)
AI 1.5-10BK (3200195)
AI 2.5-12BU (3200962)
Recommended
Pin Terminal
Crimp Tool
CRIMPFOX ZA3
(1201882)
10mm
[0.39in]
+(24V)
-(0V)
FG
Opening Button
DC power supply cord