)3 6HULHV 8VHU 0DQXDO
Preface Thank you for purchasing Digital’s TFT type color display panel, the ‘FP3000 Series’ (hereafter referred to as the FP unit). Please read this manual completely to insure the correct use and complete understanding of the FP unit’s functions. NOTICE 1. Copying this manual’s contents, either in whole or in part, is prohibited without the express permission of Digital Electronics Corporation, Japan. 2. The information contained in this manual is subject to change without notice. 3.
Essential Safety Precautions This manual describes safety instructions for correct use of the FP unit. Please keep this manual close at hand and refer to it when necessary. Safety Icons Throughout this manual, these icons provide essential safety information for FP operation procedures requiring special attention. These icons indicate the following levels of danger: Indicates situations where severe bodily injury, death or major equipment damage can occur.
In a situation that a detection function for the backlight burnout has been ineffective, if a burnout of the backlight happened, unlike in an extinction condition of the backlight of FP, the touch panel is still active. If an operator fails to notice that the backlight is burned out and touches the panel, a potentially dangerous machine miss-operation can occur. Therefore, do not set up switches on the touch panel of an FP that are likely to cause human error or physical damage triggered by mis-operation.
Avoid restricting the FP’s natural ventilation, or storing and using the FP in an environment that will increase the FP’s internal temperature. Do not use the FP in areas where sudden, large changes in temperature may occur. These changes can cause condensation to form inside the unit, possibly causing an accident. Do not store or use the FP where chemicals (such as organic solvents, etc.) and acids can evaporate, or where chemicals and acids are present in the air.
Connecting the FP to a PC The FP3000 Series is designed for the following resolutions. Series Full Resolution FP-3500T Series 640×480 FP-3600T Series 800×600 FP-3650T Series 1024×768 FP-3710T Series 1024×768 FP-3900T Series 1280×1024 Be aware that some types of devices for image signal output may not be within the ranges specified in this document, and, therefore, cannot be connected to the FP.
Information Symbols This manual uses the following icons: Indicates a warning or a product limitation. Be sure to follow the instructions given with this icon to ensure the safe operation of the FP. Contains additional or useful information. (1) (2) *1 SEE 6 Indicates steps used to accomplish a given task. Be sure to follow these steps in the order they are written. Indicates useful or important supplemental information. Indicates pages containing related information.
FP3000 Series Models The FP3000 Series refers to the following FP model numbers: Series FP-3500T Series Product Name Model Type Power input type FP3500-T11 AC None FP3500-T41-24V DC UL/c-UL/CSA Approved, CE Marked FP3600-T11 AC None FP3600-T41-24V DC UL/c-UL/CSA Approved, CE Marked FP3650-T41 AC UL/c-UL Approved, CE Marked FP3710-T41-U AC UL/c-UL/CSA Approved, CE Marked, FCC Statement FP3710-T42-U AC UL/c-UL Approved, CE Marked, FCC Statement FP3710-T41 AC UL/c-UL/CSA Approved,
FP3000 Series Package Contents The FP unit’s packing box contains the items listed below. Please check to be sure each item is included and is not damaged. FP Unit (1) Installation Guide (1) (English / Japanese) Installation Guide (This model is FP-3600T Series.
This unit has been carefully packed, with special attention to quality. However, should you find anything damaged or missing, please contact your local FP distributor immediately.
Main Features FP3000 Series displays are equipped with the following features. JFP-3500T Series • High Quality TFT Color LCD Display This unit is equipped with a 10.4 inch TFT type color LCD. This series has superb brightness and wide viewing angles, not found in ordinary laptop-type TFT LCDs. This unit screen’s maximum resolution is 640(H) × 480(V) pixels. This series can display 260,000 colors.
• Panel can be used as a VGA Display Since the FP is equipped with an analog RGB interface and a DVI-D Interface, it can be connected to a PC and other, similar devices. (The PC’s dot clock frequency, however, must be within the standard range.) • Easy-to-use Built-In Touch Panel The FP’s built-in touch panel is standard equipment, allowing touch panel data to be output to a host PC via an RS232C cable or USB cable. This is perfect for systems requiring both touch panel operation and data monitoring.
• Easy Installation In User’s Cabinets and Panels The FP’s slim and compact design makes installation a snap since it was designed specifically for use as an IA (Industrial Automation) or OA (Office Automation) system monitor. The flat, front panel provides protection equivalent to the rigorous IP65f standard. Even without its optional protective cover the front panel is highly resistant to both water and dust.
What is IP65f? This unit’s protection rating of IP65f is actually a composite code, consisting of the internationally recognized British “Ingress Protection” standard (BS EN 60529:1992) - “IP65”, and the standard developed by the Japanese Electronics Manufacturer’s Association (JEM) - “f”. This code is used in this manual to identify a given product’s degree of structural resistance to a variety of environmental elements and thus, prevent problems or accidents related to the inappropriate use of a product.
UL/c-UL/CSA Approval • UL listed products Industrial Control Equipment refer to UL508 see [a] in the “Product List“ Information Technology Equipment Safety - Part 1 refer to UL60950-1 (First Edition) see [b] in the “Product List“ Suitable for use in Class I, Division 2, Groups A, B, C, and D Hazardous (classified) locations, or Non-Hazardous Locations. refer to ANSI/ISA 12.12.01 see [c] in the “Product List“ Process Control Equipment refer to CSA-C22.2 No.
• The rear face of the FP unit is not a part of an enclosure. This unit must be used as a built-in component of an end-use product that forms a UL/c-UL-compliant enclosure. • For indoor use only. • This unit should be installed in the front face of a metal panel. • If this unit is installed so as to cool itself naturally, be sure to install it in a vertical panel. Also, be sure that the FP unit is mounted at least 100 mm away from any adjacent structures or equipment.
(2) (3) Selected Associated Nonincendive Field Wiring Apparatus shall satisfy the following: Nonincendive Field Wiring Apparatus - Front module of FP unit Voc ≤ Vmax Isc ≤ Imax Ca ≥ Ci+C cable La ≥ Li+L cable If the electrical parameters of the cable are unknown, the following values may be used: Capacitance = 60pF/ft, Inductive = 0.20 µH/ft (4) Nonincendive Field Wiring must be installed in accordance with article 501.10(B) of the National Electrical Code ANSI/NFPA 70.
FCC Statement The following Series units conform to the FCC Rules. Series FP-3710T Series FP-3900T Series United States FCC Part 15, Subpart B, Class A EMI Compliance Statement: NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
18
Table of Contents Preface........................................................................................................... 1 Essential Safety Precautions ........................................................................ 2 Connecting the FP to a PC ........................................................................... 5 Information Symbols ..................................................................................... 6 FP3000 Series Models ........................................
4.1.4 Dimensions .........................................................................................................4-13 4.2 FP-3600T Series........................................................................................... 4-16 4.2.1 General Specifications ........................................................................................4-16 4.2.2 Functional Specifications ....................................................................................4-19 4.2.
Chapter 7 Touch Panel Data 7.1 Touch Interface Data....................................................................................... 7-2 Chapter 8 Troubleshooting 8.1 Troubleshooting .............................................................................................. 8-2 8.1.1 Possible Device Problems ....................................................................................8-2 8.1.2 No Display ...................................................................................
MEMO 22
1 System Design 1. FP-3500T Series, FP-3600T Series and FP-3650T Series 2. FP-3710T Series 3.
FP3000 Series User Manual 1.1 FP-3500T Series, FP-3600T Series and FP-3650T Series The FP can be connected to Pro-face’s PS-2000B or to a Windows® compatible PC.
Chapter 1 System Design 1.2 FP-3710T Series The FP can be connected to Pro-face’s PS-2000B or to a Windows® compatible PC. FP unit Front Side USB I/F For downstream port of FP’s embedded USB-HUB (Type-A connector) *FP3710-T41-U and FP3710-T42-U only Peripherals complied with USB2.0/1.
FP3000 Series User Manual 1.3 FP-3900T Series The FP can be connected to Pro-face’s PS-2000B or to a Windows® compatible PC. FP unit Front Side USB I/F For downstream port of FP’s embedded USB-HUB (Type-A connector) *FP3900-T41-U only Peripherals complied with USB2.0/1.
2 Optional Equipment 1.
FP3000 Series User Manual 2.1 Optional Equipment All optional items listed below are products of Digital Electronics Corporation. 2.1.1 Options Model No. Corresponding FP Description Rear Cover CA1-RCVLRG-01 FP-3500T Series FP-3600T Series FP-3650T Series Attaches to the rear face of the FP unit.
Chapter 2 Optional Equipment *1 The FP-DV01-100 can be used only when the FP3650-T41, FP-3710T Series unit or FP3900T Series unit is connected to a PS-2000B unit or PL-3000B unit (Revision B or more). • Please turn on PS-2000B's internal dipswitch 4 when use FP-DV01-100 with PS2000B. (The resolution that can be displayed is 1024 x 768 Become only (XGA). ) Please turn off dipswitch 4 when use FP-DV01-50. • Please set PL-3000B's internal dipswitch 5 to z sign side when you use FP-DV01100 with PL-3000B.
FP3000 Series User Manual PC FP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 TMDS DATA2TMDS DATA2+ TMDS DATA2 SHIELD NC NC DDC Clock DDC Data NC TMDS DATA1TMDS DATA1+ TMDS DATA1 SHIELD NC NC NC GND(+5V) Hot Plug Detect TMDS DATA0TMDS DATA0+ TMDS DATA0 SHIELD NC NC TMDS CLOCK SHIELD TMDS CLOCK+ TMDS CLOCK- FG FG Input Input Input Input Input - Input Input Input Input - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 TMDS DATA2TM
Chapter 2 Optional Equipment FP SIO cable PC 1 CD Output 1 CD CD 1 Input CD 1 2 RD Output 2 RD RD 2 Input RD 2 3 SD Input 3 SD SD 3 Output SD 3 4 DTR Input 4 DTR DTR 4 Output DTR 4 5 GND - 5 GND GND 5 - GND 5 6 DSR Output 6 DSR DSR 6 Input DSR 6 7 RS Input 7 RS RS 7 Output RS 7 8 CS Output 8 CS CS 8 Input CS 8 9 NC - 9 NC RI 9 Input RI 9 FG FG - FG FG FG FG Signals and s
FP3000 Series User Manual 2.1.3 Maintenance Parts Product Name Model No. Corresponding FP FP-3500T Series FP-3600T Series FP-3650T Series GP070-AT01 Installation Fasteners Backlight 2.1.4 Metal installation fasteners.
3 Part Names and Functions 1. FP-3500T Series 2. FP-3600T Series 3. FP-3650T Series 4. FP-3710T Series 5.
FP3000 Series User Manual 3.1 FP-3500T Series A:TFT Color LCD The display monitor for your host unit. Front B:Touch Panel Allows you to switch screens or write data to the host. I C: Input Terminal Block (FP3500-T11) or Power Connector (FP3500-T41-24V) Provides the input and ground terminals for a power cable. D:Setting Switch By opening the cover, the Dip switches and slide switch are seen. Each switch can set a operation mode. A,B SEE 6.
Chapter 3 Part Names and Functions 3.2 FP-3600T Series A:TFT Color LCD The display monitor for your host unit. Front B:Touch Panel Allows you to switch screens or write data to the host. I C:Input Terminal Block (FP3600-T11) or Power Connector (FP3600-T41-24V) Provides the input and ground terminals for a power cable. D:Setting Switch By opening the cover, the Dip switches and slide switch are seen. Each switch can set a operation mode. A,B SEE 6.
FP3000 Series User Manual 3.3 FP-3650T Series A:TFT Color LCD The display monitor for your host unit. Front B:Touch Panel Allows you to switch screens or write data to the host. I C:Input Terminal Block Provides the input and ground terminals for a power cable. D:Setting Switch By opening the cover, the Dip switches and slide switch are seen. Each switch can set a operation mode. SEE A,B 6.
Chapter 3 Part Names and Functions 3.4 FP-3710T Series A:TFT Color LCD The display monitor for your host unit. Front B:Touch Panel Allows you to switch screens or write data to the host. I J C:Power Connector (socket) Provides the input and ground terminals for a power cable. D:Setting Switch By opening the cover, the Dip switches and slide switch are seen. Each switch can set a operation mode. A,B SEE 6.
FP3000 Series User Manual 3.5 FP-3900T Series A:TFT Color LCD The display monitor for your host unit. Front B:Touch Panel Allows you to switch screens or write data to the host. C:Power Connector (socket) Provides the input and ground terminals for a power cable. D:Setting Switch By opening the cover, the Dip switches and slide switch are seen. Each switch can set a operation mode. SEE A,B I 6.
4 Specifications 1. FP-3500T Series 2. FP-3600T Series 3. FP-3650T Series 4. FP-3710T Series 5. FP-3900T Series This chapter describes the general, functional and interface specifications of the FP as well as its dimensions.
FP3000 Series User Manual 4.1 FP-3500T Series 4.1.1 General Specifications Electrical specifications Items Rated Voltage Power Supply Allowable Voltage Type AC DC 24V AC100 to 240V DC19.2 to 28.8V AC85 to 265V Rated Frequency - 50 / 60Hz Rated Frequency Range - 40 to 72 Hz Allowable Voltage Drop 10ms or less 1 cycle or less (Voltage Drop Interval is 1s or more) DC 24V 2.08A or less (TYP 1.08A) AC 100V 0.90A or less (TYP 0.55A) AC 240V 0.45A or less (TYP 0.
Chapter 4 Specifications Environmental specifications Items Specifications Type DC Surrounding Air Temperature Storage Temperature Physical Ambient Operating Humidity Ambient Storage Humidity -20 to +60°C 10 to 90%RH (Wet bulb temperature: 39°C or less - no condensation.) 0.
FP3000 Series User Manual Structural specifications Items Installation Grounding Structure External Dimensions Specifications 100 Ω or less, or your country’s applicable standard. Rating*1: Equivalent to IP65f (JEM 1030) W317mm [12.48in.] × H243mm [9.57in.] × D58mm [2.28in.] Weight Cooling Method *1 Approx. 3.5kg [7.71lb] Natural air circulation The front face of the FP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification.
Chapter 4 Specifications 4.1.2 Functional Specifications Performance Items Specifications Graphics VGA (640 × 480) Display Unit 10.4 inch TFT VGA Type Resistive Film (Analog) Resolution 1024 × 1024 Service Life 1,000,000 times or more Interface Serial Interface (RS-232C), USB I/F (type-B connector) Touch Panel I/F Video I/F Analog RGB Interface, DVI-D Interface Display Items Specifications Type TFT Color LCD Resolution 640(H) × 480(V) pixels Dot Pitch 0.330mm [0.01in.] × 0.
FP3000 Series User Manual 4.1.3 Interface Specifications Analog RGB Interface Input signal type Analog RGB Input signal characteristic Image signal: analog RGB Synchronous signal: TTL level, negative polarity or positive polarity Scanning type: non-interlaced Setting via OSD (On Screen Display) • CONTRAST • H-POSITION • H-size • DIMMER (BACKLIGHT) • ALL RESET (DEFAULT) • BRIGHTNESS • V-POSITION • PHASE • SHARPNESS Display Area The number of dots (pixels) displayed are as follows. Size H.Sync.
Chapter 4 Specifications Analog RGB Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Analog R Analog G Analog B Reserved Digital grounding Return R Return G Return B Reserved Digital grounding Reserved DDC DATA 13 H. SYNC 14 V.
FP3000 Series User Manual DVI-D Interface Input signal type Setting by OSD (On Screen Display) DVI-D • CONTRAST • SHARPNESS • ALL RESET (DEFAULT) • BRIGHTNESS • DIMMER (BACKLIGHT) DIsplay Area The number of dots (pixels) displayed are as follows: Display Resolution × 1.0(H) × 1.2(V) 640 × 480 Size H.Sync. (kHz) V.Sync. (Hz) Dot Clock (MHz) 640 × 400 31.469 70.000 25.175 640 × 400 24.827 56.420 21.053 640 × 480 31.469 59.992 25.175 × 1.0 640 × 480 720 × 400*1 31.469 70.000 28.
Chapter 4 Specifications DVI-D Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Signal Name TMDS DATA2TMDS DATA2+ TMDS DATA2 SHIELD NC NC DDC Clock DDC Data NC TMDS DATA1TMDS DATA1+ TMDS DATA1 SHIELD NC Pin No. 13 14 15 16 17 18 19 20 21 22 23 24 Signal Name NC NC GND Hot Plug Detect TMDS DATA0TMDS DATA0+ TMDS DATA0 SHIELD NC NC TMDS CLOCK SHIELD TMDS CLOCK+ TMDS CLOCK- Pin Location 17 1 24 8 Connector ...........................DVI-D 24-pin male Connector set screw .
FP3000 Series User Manual Serial Interface Baud rate : 9600 bps Data length : 8 bits Serial Interface Parity : none Stop bit :1 Flow control : None RS-232C Interface Pin Assignments and Signal Names Pin No.
Chapter 4 Specifications USB Interface (Up-stream port) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Communication distance (Max): 5m The USB Interface is supported by a host PC equipped with Windows®2000(SP4) or later, or Windows®XP(SP1) or later. USB Interface Pin Assignments and Signal Names Pin No.
FP3000 Series User Manual USB Interface (Down-stream port) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Power supply voltage: 5 VDC ± 5%, Output current: 500mA (max.) Communication distance (Max): 5m Connectable USB: 127*1 Connection phase: 6 phases*1 *1 Those total numbers are based on how many a host PC can connect USB, but the numbers are not fixed, depending on the condition of the PC’s connection.
Chapter 4 Specifications Dimensions External Dimensions Unit: mm [in.] 301[11.85] Top 58[2.28] 8 [0.31] Front 227[8.94] 243[9.57] 317[12.48] Side Dimensions with installation fasteners Unit: mm [in.] 301 [11.85] 135 [5.31] 135 [5.31] Side 58 [2.28] 243[9.57] 8 [0.31] Front 227[8.94] 238.6[9.39] Top 317 [12.48] 248.6[9.79] 4.1.4 Side 135 [5.31] 135 [5.
FP3000 Series User Manual Dimensions with Cables Unit: mm [in.] 8.1[0.32] Side 243[9.57] 16[0.63] 9[0.35] 15[0.59] 25[0.98] 30[1.18] 317 [12.48] Side Rear The figure above shows a DC unit’s power terminal Bottom • All the above values are designed in case of cable bending. The dimensions given here are representative values depending on the type of connection cable used. Therefore, they are all intended for reference only. Installation Fasteners Unit: mm [in.] 11[0.43] 16 [0.63] 16.6 [0.
Chapter 4 Specifications Panel Cut Dimensions +0.04 [11.87 -0 ] Panel Cut FP r ≤ 3 [0.12] +1.0 +0.04 -0 [8.96 -0 ] +1.0 -0 227.5 301.5 • Panel thickness should be between 1.6mm [0.06in.] and 10mm [0.39in.]. Decide the panel's thickness based on the level of panel strength required. • Check that the installation panel or cabinet's surface is flat, in good condition and has no jagged edges. • Create the correct sized opening required to install the FP, using the installation dimensions given.
FP3000 Series User Manual 4.2 FP-3600T Series 4.2.1 General Specifications Electrical specifications Items Rated Voltage Power Supply Allowable Voltage Type AC DC 24V AC100 to 240V DC19.2 to 28.8V AC85 to 265V Rated Frequency - 50 / 60Hz Rated Frequency Range - 40 to 72 Hz Allowable Voltage Drop 10ms or less 1 cycle or less (Voltage Drop Interval is 1s or more) DC 24V 2.08A or less (TYP 1.30A) AC 100V 0.90A or less (TYP 0.55A) AC 240V 0.45A or less (TYP 0.
Chapter 4 Specifications Environmental specifications Items Specifications Type DC Surrounding Air Temperature Storage Temperature Physical Ambient Operating Humidity Ambient Storage Humidity -20 to +60°C 10 to 90%RH (Wet bulb temperature: 39°C or less - no condensation.) 0.
FP3000 Series User Manual Structural specifications Items Installation Grounding Structure External Dimensions Specifications 100 Ω or less, or your country’s applicable standard. Rating*1: Equivalent to IP65f (JEM 1030) W317mm [12.48in.] × H243mm [9.57in.] × D58mm [2.28in.] Weight Cooling Method *1 Approx. 3.5kg [7.71lb] Natural air circulation The front face of the FP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification.
Chapter 4 Specifications 4.2.2 Functional Specifications Performance Items Specifications Graphics SVGA (800 × 600) Display Unit 12.1 inch TFT SVGA Type Resistive Film (Analog) Resolution 1024 × 1024 Service Life 1,000,000 times or more Interface Serial Interface (RS-232C), USB I/F (type-B connector) Touch Panel I/F Video I/F Analog RGB Interface, DVI-D Interface Display Items Specifications Type TFT Color LCD Resolution 800(H) × 600(V) pixels Dot Pitch 0.3075mm[0.01in.] × 0.
FP3000 Series User Manual 4.2.3 Interface Specifications Analog RGB Interface Input signal type Analog RGB Input signal characteristic Image signal: analog RGB Synchronous signal: TTL level, negative polarity or positive polarity Scanning type: non-interlaced Setting via OSD (On Screen Display) • CONTRAST • H-POSITION • H-size • DIMMER (BACKLIGHT) • ALL RESET (DEFAULT) • BRIGHTNESS • V-POSITION • PHASE • SHARPNESS Display Area The number of dots (pixels) displayed are as follows. Size H.Sync.
Chapter 4 Specifications Analog RGB Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Analog R Analog G Analog B Reserved Digital grounding Return R Return G Return B Reserved Digital grounding Reserved DDC DATA 13 H. SYNC 14 V.
FP3000 Series User Manual DVI-D Interface Input signal type Setting by OSD (On Screen Display) DVI-D • CONTRAST • SHARPNESS • ALL RESET (DEFAULT) • BRIGHTNESS • DIMMER (BACKLIGHT) DIsplay Area The number of dots (pixels) displayed are as follows: Size H.Sync. (kHz) V.Sync. (Hz) Dot Clock (MHz) 640 × 400 31.469 70.000 25.175 640 × 400 24.827 56.420 21.053 640 × 480 31.469 59.992 25.175 640 × 480 35.000 66.670 30.240 640 × 480 37.861 72.810 31.500 720 × 400*1 31.469 70.
Chapter 4 Specifications DVI-D Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Signal Name TMDS DATA2TMDS DATA2+ TMDS DATA2 SHIELD NC NC DDC Clock DDC Data NC TMDS DATA1TMDS DATA1+ TMDS DATA1 SHIELD NC Pin No. 13 14 15 16 17 18 19 20 21 22 23 24 Signal Name NC NC GND Hot Plug Detect TMDS DATA0TMDS DATA0+ TMDS DATA0 SHIELD NC NC TMDS CLOCK SHIELD TMDS CLOCK+ TMDS CLOCK- Pin Location 17 1 24 8 Connector ...........................DVI-D 24-pin male Connector set screw .
FP3000 Series User Manual Serial Interface Baud rate : 9600 bps Data length : 8 bits Serial Interface Parity : none Stop bit :1 Flow control : None RS-232C Interface Pin Assignments and Signal Names Pin No.
Chapter 4 Specifications USB Interface (Up-stream port) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Communication distance (Max): 5m The USB Interface is supported by a host PC equipped with Windows®2000(SP4) or later, or Windows®XP(SP1) or later. USB Interface Pin Assignments and Signal Names Pin No.
FP3000 Series User Manual USB Interface (Down-stream port) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Power supply voltage: 5 VDC ± 5%, Output current: 500mA (max.) Communication distance (Max): 5m Connectable USB: 127*1 Connection phase: 6 phases*1 *1 Those total numbers are based on how many a host PC can connect USB, but the numbers are not fixed, depending on the condition of the PC’s connection.
Chapter 4 Specifications Dimensions External Dimensions Unit: mm [in.] 301[11.85] Top 58[2.28] 317[12.48] 243[9.57] 227[8.94] 8 [0.31] Side Front Dimensions with installation fasteners Unit: mm [in.] 301 [11.85] 135 [5.31] 135 [5.31] 58 [2.28] Top Side 243[9.57] 8 [0.31] Front 227[8.94] 238.6[9.39] 317 [12.48] 248.6[9.79] 4.2.4 Side 135 [5.31] 135 [5.
FP3000 Series User Manual Dimensions with Cables Unit: mm [in.] 8.1[0.32] Side 243[9.57] 16[0.63] 9[0.35] 15[0.59] 25[0.98] 30[1.18] 317 [12.48] Side Rear The figure above shows a DC unit’s power terminal Bottom • All the above values are designed in case of cable bending. The dimensions given here are representative values depending on the type of connection cable used. Therefore, they are all intended for reference only. Installation Fasteners Unit: mm [in.] 11[0.43] 16 [0.63] 16.6 [0.
Chapter 4 Specifications Panel Cut Dimensions +0.04 [11.87 -0 ] Panel Cut FP r ≤ 3 [0.12] +1.0 +0.04 -0 [8.96 -0 ] +1.0 -0 227.5 301.5 • Panel thickness should be between 1.6mm [0.06in.] and 10mm [0.39in.]. Decide the panel's thickness based on the level of panel strength required. • Check that the installation panel or cabinet's surface is flat, in good condition and has no jagged edges. • Create the correct sized opening required to install the FP, using the installation dimensions given.
FP3000 Series User Manual 4.3 FP-3650T Series 4.3.1 General Specifications Electrical specifications Power Supply Items Specifications Rated Voltage AC100 to 240V Allowable Voltage AC85 to 265V Rated Frequency 50 / 60Hz Rated Frequency Range 40 to 72 Hz Allowable Voltage Drop 1 cycle or less (Voltage Drop Interval is 1s or more) AC 100V 0.90A or less (TYP 0.55A) AC 240V 0.45A or less (TYP 0.
Chapter 4 Specifications Structural specifications Items Installation Grounding Structure External Dimensions Specifications 100 Ω or less, or your country’s applicable standard. Rating*1: Equivalent to IP65f (JEM 1030) W317mm [12.48in.] × H243mm [9.57in.] × D58mm [2.28in.] Weight Cooling Method *1 Approx. 3.5kg [7.71lb] Natural air circulation The front face of the FP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification.
FP3000 Series User Manual 4.3.2 Functional Specifications Performance Items Specifications Graphics XGA (1024 × 768) Display Unit 12.1 inch TFT XGA Type Resistive Film (Analog) Resolution 1024 × 1024 Service Life 1,000,000 times or more Interface Serial Interface (RS-232C), USB I/F (type-B connector) Touch Panel I/F Video I/F Analog RGB Interface, DVI-D Interface Display Items Specifications Type TFT Color LCD Resolution 1024(H) × 768(V) pixels Dot Pitch 0.24mm[0.01in.] × 0.
Chapter 4 Specifications 4.3.3 Interface Specifications Analog RGB Interface Input signal type Analog RGB Input signal characteristic Image signal: analog RGB Synchronous signal: TTL level, negative polarity or positive polarity Scanning type: non-interlaced Setting via OSD (On Screen Display) • CONTRAST • H-POSITION • H-size • DIMMER (BACKLIGHT) • ALL RESET (DEFAULT) • BRIGHTNESS • V-POSITION • PHASE • SHARPNESS Display Area The number of dots (pixels) displayed are as follows. Size H.Sync.
FP3000 Series User Manual Analog RGB Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Analog R Analog G Analog B Reserved Digital grounding Return R Return G Return B Reserved Digital grounding Reserved DDC DATA 13 H. SYNC 14 V.
Chapter 4 Specifications DVI-D Interface Input signal type Setting by OSD (On Screen Display) DVI-D • CONTRAST • SHARPNESS • ALL RESET (DEFAULT) • BRIGHTNESS • DIMMER (BACKLIGHT) DIsplay Area The number of dots (pixels) displayed are as follows: Size H.Sync. (kHz) V.Sync. (Hz) Dot Clock (MHz) 640 × 400 24.827 56.420 21.053 640 × 400 31.469 70.000 25.175 640 × 480 31.469 59.992 25.175 640 × 480 37.500 75.000 31.500 640 × 480 35.000 66.667 30.240 720 × 400*1 31.469 70.
FP3000 Series User Manual DVI-D Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Signal Name TMDS DATA2TMDS DATA2+ TMDS DATA2 SHIELD NC NC DDC Clock DDC Data NC TMDS DATA1TMDS DATA1+ TMDS DATA1 SHIELD NC Pin No. 13 14 15 16 17 18 19 20 21 22 23 24 Signal Name NC NC GND Hot Plug Detect TMDS DATA0TMDS DATA0+ TMDS DATA0 SHIELD NC NC TMDS CLOCK SHIELD TMDS CLOCK+ TMDS CLOCK- Pin Location 17 1 24 8 Connector...........................
Chapter 4 Specifications Serial Interface Baud rate : 9600 bps Data length : 8 bits Serial Interface Parity : none Stop bit :1 Flow control : None RS-232C Interface Pin Assignments and Signal Names Pin No.
FP3000 Series User Manual USB Interface (Up-stream port) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Communication distance (Max): 5m The USB Interface is supported by a host PC equipped with Windows®2000(SP4) or later, or Windows®XP(SP1) or later. USB Interface Pin Assignments and Signal Names Pin No.
Chapter 4 Specifications USB Interface (Down-stream port) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Power supply voltage: 5 VDC ± 5%, Output current: 500mA (max.) Communication distance (Max): 5m Connectable USB: 127*1 Connection phase: 6 phases*1 *1 Those total numbers are based on how many a host PC can connect USB, but the numbers are not fixed, depending on the condition of the PC’s connection.
FP3000 Series User Manual 4.3.4 Dimensions External Dimensions Unit: mm [in.] 301[11.85] Top 58[2.28] 317[12.48] 243[9.57] 227[8.94] 8 [0.31] Side Front Dimensions with installation fasteners Unit: mm [in.] 301 [11.85] 135 [5.31] 135 [5.31] 58 [2.28] Top Side Front 135 [5.31] 135 [5.31] Bottom 4-40 227[8.94] 238.6[9.39] 8 [0.31] 243[9.57] 248.6[9.79] 317 [12.
Chapter 4 Specifications Dimensions with Cables Unit: mm [in.] Side 243[9.57] 16[0.63] 9[0.35] 15[0.59] 25[0.98] 30[1.18] 317 [12.48] Side Rear Bottom • All the above values are designed in case of cable bending. The dimensions given here are representative values depending on the type of connection cable used. Therefore, they are all intended for reference only. Installation Fasteners Unit: mm [in.] 11[0.43] 16 [0.63] 16.6 [0.65] 31 [1.22] ∅10[0.
FP3000 Series User Manual Panel Cut Dimensions Unit: mm [in.] +0.04 [11.87 -0 ] Panel Cut FP r ≤ 3 [0.12] +1.0 +0.04 -0 [8.96 -0 ] +1.0 -0 227.5 301.5 • Panel thickness should be between 1.6mm [0.06in.] and 10mm [0.39in.]. Decide the panel's thickness based on the level of panel strength required. • Check that the installation panel or cabinet's surface is flat, in good condition and has no jagged edges.
Chapter 4 Specifications 4.4 FP-3710T Series General Specifications Electrical specifications Items Power Supply 4.4.1 Specifications Rated Voltage AC100 to 240V Allowable Voltage AC85 to 264V Rated Frequency 50 / 60Hz Rated Frequency Range 40 to 72 Hz Allowable Voltage Drop 1 cycle or less (Voltage Drop Interval is 1s or more) Current Consumption In-Rush Current AC 100V 1.1A or less (TYP 0.75A) AC 240V 0.7A or less (TYP 0.
FP3000 Series User Manual Environmental specifications Items Specifications Surrounding Air Temperature Storage Temperature -20 to +60°C Physical Ambient Operating Humidity Ambient Storage Humidity 0.1mg/m3 or less (No electrically conductive dust is allowed) Pollution Degree For use in Pollution Degree 2 environment Free of corrosive gas Atomospherical pressure Resistance Mechanical 10 to 90%RH (Wet bulb temperature: 39°C or less - no condensation.
Chapter 4 Specifications *1 The front face of the FP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the FP unit’s level of resistance is equivalent to these standards, oils that should have no effect on the FP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time.
FP3000 Series User Manual 4.4.2 Functional Specifications Performance Items Specifications Graphics XGA (1024 × 768) Display Unit 15 inch TFT XGA Touch Panel I/F Type Resistive Film (Analog) Resolution 1024 × 1024 Service Life 1,000,000 times or more Interface Serial Interface (RS-232C) USB Interface (Type-B connector) Analog RGB Interface DVI-D Interface Video I/F Display Items Specifications Size 38cm(15 in.) (Meas.
Chapter 4 Specifications 4.4.3 Interface Specifications Analog RGB Interface Input signal type Analog RGB Input signal characteristic Image signal: analog RGB Synchronous signal: TTL level, negative polarity or positive polarity Scanning type: non-interlaced Setting via OSD (On Screen Display) • CONTRAST • H-POSITION • H-size • DIMMER (BACKLIGHT) • ALL RESET (DEFAULT) • BRIGHTNESS • V-POSITION • PHASE • SHARPNESS Display Area The number of dots (pixels) displayed are as follows. Size H.Sync.
FP3000 Series User Manual Analog RGB Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Analog R Analog G Analog B Reserved Digital grounding Return R Return G Return B Reserved Digital grounding Reserved DDC DATA 13 H. SYNC 14 V.
Chapter 4 Specifications DVI-D Interface Input signal type Setting by OSD (On Screen Display) DVI-D • CONTRAST • SHARPNESS • ALL RESET (DEFAULT) • BRIGHTNESS • DIMMER (BACKLIGHT) DIsplay Area The number of dots (pixels) displayed are as follows: Size H.Sync. (kHz) V.Sync. (Hz) Dot Clock (MHz) 640 × 400 24.827 56.420 21.053 640 × 400 31.469 70.000 25.175 640 × 480 31.469 59.992 25.175 640 × 480 37.500 75.000 31.500 640 × 480 35.000 66.670 30.240 720 × 400*1 31.469 70.
FP3000 Series User Manual DVI-D Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Signal Name TMDS DATA2TMDS DATA2+ TMDS DATA2 SHIELD NC NC DDC Clock DDC Data NC TMDS DATA1TMDS DATA1+ TMDS DATA1 SHIELD NC Pin No. 13 14 15 16 17 18 19 20 21 22 23 24 Signal Name NC NC GND Hot Plug Detect TMDS DATA0TMDS DATA0+ TMDS DATA0 SHIELD NC NC TMDS CLOCK SHIELD TMDS CLOCK+ TMDS CLOCK- Pin Location 17 1 24 8 Connector...........................
Chapter 4 Specifications Serial Interface Baud rate : 9600 bps Data length : 8 bits Serial Interface Parity : none Stop bit :1 Flow control : None RS-232C Interface Pin Assignments and Signal Names Pin No.
FP3000 Series User Manual USB Interface (Up-stream port) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Communication distance (Max): 5m The USB Interface is supported by a host PC equipped with Windows®2000(SP4) or later, or Windows®XP(SP1) or later. USB Interface Pin Assignments and Signal Names Pin No.
Chapter 4 Specifications Front USB Interface (Down-stream port) (FP3710-T41-U and FP3710-T42-U model only) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Power supply voltage: 5 VDC ± 5%, Output current: 500mA (max.
FP3000 Series User Manual 4.4.4 Dimensions External Dimensions Unit: mm [in.] 383 [15.08] Top 395 [15.55] 282 [11.10] 294 [11.57] 60 [2.36] 5 [0.20] Front Side Dimensions with installation fasteners Unit: mm [in.] 395[15.55] 160 [6.30] Side Front 165 [6.50] 160 [6.30] 405 [15.94] Bottom 4-54 60 [2.36] 5 [0.20] 294[11.57] 294[11.57] 304[11.97] 237.5[9.35] 383 [15.08] Top 395 [15.55] 282[11.10] 160 [6.
Chapter 4 Specifications Dimensions with Cables Unit: mm [in.] 20[0.79] 25[0.98] 35[1.38] 40[1.57] 294[11.57] 395 [15.55] Rear Side Side Bottom • All the above values are designed in case of cable bending. The dimensions given here are representative values depending on the type of connection cable used. Therefore, they are all intended for reference only. Installation Fasteners Unit: mm [in.] 11[0.43] 16 [0.63] 16.6 [0.65] 31 [1.22] ∅10[0.
FP3000 Series User Manual Panel Cut Dimensions Unit: mm [in.] +1.0 -0 +0.04 [15.10 -0 ] Panel Cut 282.5 FP r ≤ 3 [0.12] +1.0 +0.04 ] -0 [11.12 -0 383.5 • Panel thickness should be between 1.6mm [0.06in.] and 10mm [0.39in.]. Decide the panel's thickness based on the level of panel strength required. • Check that the installation panel or cabinet's surface is flat, in good condition and has no jagged edges.
Chapter 4 Specifications 4.5 FP-3900T Series General Specifications Electrical specifications Power Supply Items Specifications Rated Voltage AC100 to 240V Allowable Voltage AC85 to 264V Rated Frequency 50 / 60Hz Rated Frequency Range 40 to 72 Hz Allowable Voltage Drop 1 cycle or less (Voltage drop interval must be 1s or more) Current Consumption In-Rush Current AC 100V 1.1A or less (TYP 0.75A) AC 240V 0.7A or less (TYP 0.
FP3000 Series User Manual Structural specifications Items Installation Grounding Structure External Dimensions Specifications 100 Ω or less, or your country’s applicable standard. Rating*1: Equivalent to IP65f (Only not using Front USB) figuration: Built-in type Installation method: Embedding W460mm [18.11in.] × H390mm [15.35in.] × D77.7mm [3.06in.] Weight Cooling Method *1 Approx. 10.0kg [22.
Chapter 4 Specifications 4.5.2 Functional Specifications Performance Items Specifications Graphics SXGA (1280 × 1024) Display Unit 19 inch TFT SXGA Touch Panel I/F Type Resistive Film (Analog) Resolution 1024 × 1024 Service Life 35,000,000 times or more Interface Serial Interface (RS-232C) USB Interface (Type-B connector) Analog RGB Interface DVI-D Interface Video I/F Display Items Specifications Size 48cm(19 in.) (Meas.
FP3000 Series User Manual 4.5.3 Interface Specifications Analog RGB Interface Input signal type Analog RGB Input signal characteristic Image signal: analog RGB Synchronous signal: TTL level, negative polarity or positive polarity Scanning type: non-interlaced Setting via OSD (On Screen Display) • CONTRAST • H-POSITION • H-size • DIMMER (BACKLIGHT) • ALL RESET (DEFAULT) • BRIGHTNESS • V-POSITION • PHASE • SHARPNESS Display Area The number of dots (pixels) displayed are as follows. Size H.Sync.
Chapter 4 Specifications Analog RGB Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Analog R Analog G Analog B Reserved Digital grounding Return R Return G Return B Reserved Digital grounding Reserved DDC DATA 13 H. SYNC 14 V.
FP3000 Series User Manual DVI-D Interface Input signal type Setting by OSD (On Screen Display) DVI-D • CONTRAST • SHARPNESS • ALL RESET (DEFAULT) • BRIGHTNESS • DIMMER (BACKLIGHT) DIsplay Area The number of dots (pixels) displayed are as follows:. Size H.Sync. (kHz) V.Sync. (Hz) Dot Clock (MHz) Screen Resolution Expansion (H: Horizontal) (V: Vertical) 640 × 400 31.469 70.000 25.175 × 2(H) × 2.56(V) 1280 × 1024 640 × 480 31.469 59.992 25.175 640 × 480 35.000 66.670 30.240 37.
Chapter 4 Specifications DVI-D Interface Pin Assignments and Signal Names Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Signal Name TMDS DATA2TMDS DATA2+ TMDS DATA2 SHIELD NC NC DDC Clock DDC Data NC TMDS DATA1TMDS DATA1+ TMDS DATA1 SHIELD NC Pin No. 13 14 15 16 17 18 19 20 21 22 23 24 Signal Name NC NC GND Hot Plug Detect TMDS DATA0TMDS DATA0+ TMDS DATA0 SHIELD NC NC TMDS CLOCK SHIELD TMDS CLOCK+ TMDS CLOCK- Pin Location 17 1 24 8 Connector ...........................
FP3000 Series User Manual Serial Interface Baud rate : 9600 bps Data length : 8 bits Serial Interface Parity : none Stop bit :1 Flow control : None RS-232C Interface Pin Assignments and Signal Names Pin No.
Chapter 4 Specifications USB Interface (Up-stream port) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Communication distance (Max): 5m The USB Interface is supported by a host PC equipped with Windows®2000(SP4) or later, or Windows®XP(SP1) or later. USB Interface Pin Assignments and Signal Names Pin No.
FP3000 Series User Manual Front USB Interface (Down-stream port) (FP3900-T41-U model only) USB 2.0/1.1 compliant • Low (1.5 Mbps) Supported speed • Full (12 Mbps) • Hi (480 Mbps) USB Interface Power supply voltage: 5 VDC ± 5%, Output current: 500mA (max.) Communication distance (Max): 5m Connectable USB: 127*1 Connection phase: 6 phases*1 *1 Those total numbers are based on how many a host PC can connect USB, but the numbers are not fixed, depending on the condition of the PC’s connection.
Chapter 4 Specifications Dimensions External Dimensions Unit: mm [in.] 419[16.50] 100[3.94] center of unit 5 [0.20] Side Front 8-M4 Effective Screw Depth 7 [0.28] 352[13.86] 2.5[0.10] 390[15.35] center of display area center of VESA 75 [2.95] 5[0.20] 12.7 [0.50] 460[18.11] 77.7 3.5 [3.06] [0.14] 75 [2.95] 100 [3.94] Top Rear Dimensions with installation fasteners Unit: mm [in.] 431[16.97] 360[14.17] 419[16.50] Top 460[18.11] Side Front 352[13.86] 2.5[0.10] 16[0.63] 16[0.63] 232[9.
FP3000 Series User Manual Dimensions with Cables Side 24[0.94] 4[0.16] 28[1.10] 7[0.28] 59[2.32] Unit: mm [in.] Rear Side Bottom • All the above values are designed in case of cable bending. The dimensions given here are representative values depending on the type of connection cable used. Therefore, they are all intended for reference only. Installation Fasteners Unit: mm [in.] 11[0.43] 16 [0.63] 16.6 [0.65] 31 [1.22] ∅10[0.
Chapter 4 Specifications Panel Cut Dimensions Unit: mm [in.] +1.0 -0 +0.04 [16.52 -0 ] Panel Cut 352.5 FP r ≤ 3 [0.12] +1.0 +0.04 ] -0 [13.88 -0 419.5 • Panel thickness should be between 1.6mm [0.06in.] and 10mm [0.39in.]. Decide the panel's thickness based on the level of panel strength required. • Check that the installation panel or cabinet's surface is flat, in good condition and has no jagged edges.
FP3000 Series User Manual 4-70
5 Installation and Wiring 1. Installation 2. Wiring This chapter explains the installation method and the wiring method for the FP.
FP3000 Series User Manual 5.1 Installation 5.1.1 Installation Procedures Follow the steps given below when installing the FP. Check the Installation Gasket’s Seating It is strongly recommended that you use the installation gasket, since it absorbs vibration in addition to repelling water. Place the FP on a level surface with the display panel facing downward. Check that the FP’s installation gasket is seated securely into the gasket’s groove, which runs around the perimeter of the panel’s frame.
Chapter 5 Installation and Wiring Creating a Panel Cut Create the correct sized opening required to install the FP, using the installation dimensions given. The installation gasket, installation fasteners and attachment screws are all required when installing the FP. Decide the panel's thickness based on the level of panel strength required.
FP3000 Series User Manual • Be sure that the ambient operating temperature and the surrounding operating humidity are within their designated ranges. (When installing the FP in a cabinet or an enclosure, “Ambient operation temperature” indicates both the panel face and cabinet or enclosure's internal temperature.). Unit: mm [in.] 100 [3.94] 100 [3.94] 30 [1.18] Panel Face 30 [1.
Chapter 5 Installation and Wiring Installing the FP (1) Insert the FP into the panel cut, as shown here. Panel Panel Cut FP Panel Side (2) Insert the installation fasteners into the FP’s insertion slots.
FP3000 Series User Manual FP-3710T Series Top Insertion Slots Left side FP-3900T Series Right side Bottom Top Insertion Slots Left side Right side Bottom Installation panel Hook 5-6
Chapter 5 Installation and Wiring (3) Insert each of the fasteners as shown below. Be sure to pull the fastener back until it is flush with the rear of the attachment hole. (4) Tighten the fastener screws equally in a diagonal pattern by using a Phillips screw driver. When tightening them, slowly increase the torque. (FP-3500T/3600T/3650T Series: 4 places, FP-3710T Series: 8 places, FP-3900T Series: 12 places) • Do not use too much force, since it may damage the FP unit. A torque of only 0.
FP3000 Series User Manual 5.2 Wiring 5.2.1 Connecting the Power Cord To avoid an electric shock, when connecting the FP’s power cord terminals to the power terminal block, confirm that the FP’s power supply is completely turned OFF, via a breaker, or similar unit. To avoid the dangers of fire, electric hazards and equipment damage, be sure to use only the specified voltage when operating the FP. Since there is no power switch on the FP unit, be sure to attach a breaker-type switch to its power cord.
Chapter 5 Installation and Wiring Connecting the FP Power Cord (1) Be sure that the FP’s power cord is not plugged in to the power supply. (2) Remove the Terminal Strip's clear plastic cover. (3) Remove the screws from the two (2) terminals (L,N) and FG (Frame Ground) Terminal, position the Ring Terminals and reattach the screws.
FP3000 Series User Manual Power connector specification FG + 24V - 0V FG A frame ground terminal connected with FP unit + - Power Cable Joint • Kind of power cord is CA5-DCCNL-01 which are Digital products, or GMVSTBW2,5/3-STF*1 7,62 which are Phoenix Contact*1 products. Please contact Phoenix Contact for the details. Wiring Use the following wiring for FP. Those are Phoenix Contact products. Recommended Drivers SZF 1-0.6x3.5 (1204517) AI 0.
Chapter 5 Installation and Wiring (5) Fix all of them with screws. + - FG • Use a minus driver when fixing terminal screws. The necessary torque is 0.5 - 0.6 N•m [5 - 7 Lb•in.]. • Cable joints are not allowed to solder. • Ensure that the power cable is twisted where it is near the connector. (6) Install the connector in the FP. With the installation screws on the both sides of the connector, fix them firmly. FP-3710T/3900T Series (AC type) Power Cable specification Use copper conductors only.
FP3000 Series User Manual Power connector specification L AC Input Terminal-live line N AC Input Terminal-neutral line FG Ground Terminal connected to the FP chassis L N FG Power Cable Joint • Kind of power cord is FKC 2,5/3-STF-5,08 which are Phoenix Contact*1 products. *1 Please contact Phoenix Contact for the details. Wiring Use the following wiring for FP. Those are Phoenix Contact products. Recommended Drivers SZS 0.6X3.5 (1205053) AI 0.
Chapter 5 Installation and Wiring (4) After inserting all three pins, insert the Power Plug into the Power Connector at FP. Fix the plug with two(2) minus screws. • Confirm that all wires are connected correctly. • The torque required to tighten these screws is 0.5 N•m - 0.6 N•m. • To prevent the possibility of a terminal short, use a pin terminal that has an insulating sleeve. 5.2.
FP3000 Series User Manual USB Cable Clamp Attachment Procedure (1) Connect the USB cable to the connector. (2) Insert the cable clamp into the cable clamp holder as shown in figure 1, and tighten the clamp until the cable is secured in place. USB Cable USB cable clamp Stopper USB cable clamp holder Figure 1 USB Cable Clamp Removal Procedure 5-14 (1) Push in the cable clamp’s stopper until the cable clamp is unlocked, then remove the clamp.
Chapter 5 Installation and Wiring 5.2.3 Connecting the Power Supply • If the power supply voltage exceeds the FP unit’s spec- Twisted-pair cord Constant Voltage Transformer FP Unit FG ified range, connect a constant voltage transformer. SEE 4 Specifications (page4-1) • For between the line and ground or between the lines, select a power supply that is low in noise. If there is an excess amount of noise, connect an insulating transTwisted-pair cord FP Unit Insulating Transformer former.
FP3000 Series User Manual 5.2.4 Precautions: Grounding (a) Exclusive grounding (BEST) • Connect the FP’s FG terminal to an exclusive ground. [diagram (a) - Grounding resistance of under 100Ω.] FP Unit Other Equipment • If exclusive grounding is not possible, use a common (b) Common grounding (OK) connection point. [diagram (b)] FP Unit Other Equipment • The grounding wire should have a cross sectional area greater than 2mm2.
6 Setting up and Adjusting the FP unit 1. Operation Mode Setup 2. Screen Display Adjustment This chapter describes the settings of the operation mode and the OSD.
FP3000 Series User Manual 6.1 Operation Mode Setup 6.1.1 Preset Settings and Adjustments for Dip Switch and Slide Switch The Dip Switches and Slide Switch are located in the bottom of the FP unit. Only the settings when the power supply is turned on is effective to the Dip Switches and the Slide Switch. Before operating the Dip Switches and Slide Switch, be sure to turn off the power.
Chapter 6 Setting up and Adjusting the FP unit The factory default for the FP unit’s Dip Switches and Slide Switch are as follows. SW1 1 2 3 4 5 6 7 8 ON • SW1-1 Reserved (Always OFF) SW1-2 Display/Hide the OSD SW1-3 Reserved (Always OFF) SW1-4 Reserved (Always OFF) SW1-5 Reserved (Always OFF) SW1-6 Reserved (Always OFF) SW1-7 Reserved (Always OFF) SW1-8 Reserved (Always OFF) SW1-2 Dip Switch SW1-2 is used to display or hide the OSD. To hide the OSD, set the switch to ON.
FP3000 Series User Manual 6.1.2 Status of Front LED in Operation Modes OFF Green Orange Green/ Red Flash Orange Flash*1 Power OFF Power ON Power ON Power ON Power ON Backlight - Normal Normal Burned-out Burned-out Input of Image - Yes No Yes No LED Panel *1 6-4 Only while “No signal” is displayed.
Chapter 6 Setting up and Adjusting the FP unit 6.2 Screen Display Adjustment 6.2.1 Calibration of OSD Display Position You can operate the FP screen menus via the touch panel, and adjust screen image display to a minute level. The feature is called OSD (On Screen Display). This section describes items and functions that can be set with OSD.
FP3000 Series User Manual • In the OSD, pressing the button applies the set value and enables the setting. The set value won't be canceled unless the power is turned OFF or the value is reset. If the power is turned OFF without saving the set value, that data will disappear. The last saved data will be read into the system when the FP starts. To enable the changed value, be sure to press the button.
Chapter 6 Setting up and Adjusting the FP unit 6.2.2 OSD Setting Icons Item Function Color Settings Adjusts the contrast and the brightness. Screen Settings Adjusts the display position of the screen. Custom Display Adjusts Sharpness and the backlight brightness. System Settings Changes settings such as activating the click sound. All Reset Resets the current OSD value to the default value. Input Source Switches Analog RGB and DVI-D.
FP3000 Series User Manual 6.2.3 OSD Setting Item Details Main Menu Color Settings Selection of the change item Contrast Adjusts the contrast. R.Contrast Adjusts the R.contrast. G.Contrast Adjusts the G.contrast. B.Contrast Adjusts the B.contrast. Brightness Adjusts the Brightness. Adjustment button Applies the setting and then returns to the top menu. Cancels the setting and then returns to the top menu. Screen Settings Selection of the change item Adjustment button H.
Chapter 6 Setting up and Adjusting the FP unit System Settings Selection of the change item Adjustment button Click Tone Enables/disables the click sound. With this parameter, the sound level can also be adjusted. (Default value: OFF ) 720x400 Mode When an input data resolution of 720 x 400 is used in the VGA text mode, set this parameter to ON. For other resolutions, set this parameter to OFF.
FP3000 Series User Manual All Reset Resets all the settings and then returns to the top menu. Cancels the setting and then returns to the top menu. Input Source Switches Analog RGB and DVI-D, and quits the OSD. Cancels the setting and then returns to the top menu. Auto Adjust (Analog RGB only) Applies the setting and then returns to the top menu. Cancels the setting and then returns to the top menu. • Be sure to perform the auto adjust while things except the black are displayed on the edge of the screen.
7 Touch Panel Data 1. Touch Interface Data This chapter describes the outline of the software to input the touch panel data to the host computer.
FP3000 Series User Manual 7.1 Touch Interface Data The FP3000 Series units use an analog type touch panel. This touch panel needs a calibration program to adjust the actual touch position. The display resolutions are 640 × 480 for FP-3500T Series units, 800 × 600 for FP-3600T Series units, 1024 × 768 for FP3650-T41 units, 1024 × 768 for FP-3710T Series units, and 1280 × 1024 for FP-3900T Series units. The screen display origin point is at the upper left corner of the screen.
Chapter 7 Touch Panel Data Touch Panel Coordinates (0,0) Display Coordinates (0,0) Touch Panel Coordinates (1023,1023) Display Coordinates FP3650-T41, FP-3710T Series (1023,767) FP-3900T Series (1279,1023) 7-3
FP3000 Series User Manual (2) Data Format Touch Panel coordinate data is sent to the host using the following format. All data is in binary format. Header: 1 byte (11h= touched; 10h = released) X coordinate: 2 bytes (0 to 3FFh) Y coordinate: 2 bytes (0 to 3FFh) X coordinate Y coordinate 10h 11h Added when touch is released. If the coordinate (X=23(11h), Y=500(1F4h)) is touched and moved to the coordinate (X=63(3Fh), Y=250(FAh)).
8 Troubleshooting 1. Troubleshooting 2.
FP3000 Series User Manual 8.1 Troubleshooting 8.1.1 Possible Device Problems This chapter explains the main method of dealing with the trouble in the use of the FP. • For problems other than problems of the FP, please refer to the manual of each equipment. Possible types of trouble while using this unit are as follows. No display • No display appears after the unit is switched on. • The screen disappears during standard operation. • The screen does not display normally.
Chapter 8 Troubleshooting 8.1.2 No Display When the screen does not display when powering up, or if the screen turns OFF by itself, use the flowchart below to find an appropriate solution. No Screen Display YES Does the backlight (CCFL) light up? NO NO Is it using the correct power voltage? Connect the appropriate voltage. SEE 4 Specifications (page4-1) YES Turn OFF the power switch. Is the power supply cable connected properly to the unit? NO Fix the power cable connection.
FP3000 Series User Manual NO Is the PC operating? Start the PC. YES Are the FP output settings the same as the PC's frequency and resolution? NO Set the FP output settings so that they match the PC’s frequency and resolution. YES NO Is the RGB cable/ DVI-D cable connected correctly? Connect the RGB cable/DVI-D cable correctly. SEE Optional Cable Diagrams (page2-3) YES Does the screen display though display is not normal. YES NO There is a problem with the FP unit.
Chapter 8 Troubleshooting 8.1.3 Touch Panel Does Not Respond When the touch panel does not react, or its reaction is very slow after it is pressed, follow the flowchart below to find the origin of the problem and the appropriate solution. Touch panel is not working Is the Mouse Emulation Software installed in PC (Host)?. NO Install the Mouse Emulation Software. For details, Refer to the “Installation Guide” (PDF file) which is supplied with the Mouse Emulation Software.
FP3000 Series User Manual 8.2 Error Message This section explains the messages that appear when an error has occurred in the FP unit during RUN mode.The problem causing the error message and its related countermeasure are explained in the table below. (Only the latest error message will appear on the FP screen) 8.2.1 Error Message List Error Message Problem Signal timing has been input that is not compatible with the FP unit.
9 Maintenance 1. Regular Cleaning 2. Periodic Check Points 3. Backlight Replacement This chapter indicates necessary cautions and inspection criteria to maintain your FP.
FP3000 Series User Manual 9.1 Regular Cleaning 9.1.1 Cleaning the Display When the display surface or frame OK! become dirty, use a soft cloth moistened with neutral detergent to wipe away any dust or stains. Neutral detergent NG! Display Do not clean the unit with thinner, organic solvents, or strong acids. Thinner Organic solvent Strong acid Do not use sharp or hard objects, such as a mechanical pencil or screwdriver, to push on the display. This could damage the unit.
Chapter 9 Maintenance 9.1.2 Replacing the Installation Gasket The installation gasket protects the FP and improves its water resistance. For instructions on installing the FP unit's gasket, refer to the following page. SEE 5 Installation and Wiring (page5-1) • A gasket which has been used for a long period of time may have scratches or dirt on it, and could have lost much of its water resistance. Be sure to change the gasket at least once a year, or when scratches or dirt become visible.
FP3000 Series User Manual • The gasket must be inserted correctly into the groove for the FP unit’s moisture resistance to be equivalent to IP65f. • Since the gasket is flexible but not elastic, be careful not to stretch it unnecessarily, as doing so could tear the gasket. • Be sure the gasket's seam is not inserted into any of the unit's corners, only in the straight sections of the groove. Inserting it into a corner may lead to its eventually tearing.
Chapter 9 Maintenance 9.2 Periodic Check Points To keep your FP unit in its best condition, please inspect the following points periodically.
FP3000 Series User Manual 9.3 Backlight Replacement • FP-3900T series backlights cannot be replaced by customers. When you need to replace the backlight of your FP-3900T, contact your local distributor. The backlight is a cold-cathode tube. Although the FP uses a long-life backlight, replacement may be required earlier than expected depending on the environment where the FP is used. It is recommended that it be replaced periodically.
Chapter 9 Maintenance • Please check that the replacement backlight is compatible with the FP. FP Model Backlight Model FP3500-T11 GP577RT-BL00-MS FP3500-T41-24V FP3600-T11 CA3-BLU12-01 FP3600-T41-24V FP3650-T41 CA5-BLU12XGA-01 FP3710-T41-U CA3-BLU15-01 FP3710-T41 FP3710-T42-U CA7-BLU15-01 FP3710-T42 Backlight Replacement Follow the procedures given below to replace the FP unit’s backlights. Be sure to wear gloves during replacement.
FP3000 Series User Manual (2) The cover is fastened at the bottom, and hinges open. • Be sure not to break the rear cover’s four (4) alignment tabs when you open it. • To prevent FP unit damage, be sure the FP unit's rear cover open/close direction is correct. (3) Loosen the three (3) circuit board attachment screws. Attachment Screws (4) The circuit board is connected on one side, and hinges open.
Chapter 9 Maintenance (5) Disconnect the upper backlight's two (2) power connectors. Connector (6) Loosen the upper and lower backlight holder attachment screws, and remove the upper backlight unit's metal cover. Attachment Screws • Since the attachment screws are small, be sure not to lose them or allow them to fall inside the FP's case. (7) Remove the old backlight.
FP3000 Series User Manual (8) Insert the new backlight. Upper Section Lower Section • The FP unit’s upper and lower backlights are different. Be sure to confirm that the backlight you are replacing is the correct unit by looking at the side of the backlight connector. If the backlight has an arrow here, it is used only for the upper backlight. (9) Insert the metal cover's three (3) positioning tabs into the LCD holder’s positioning slots. Next, insert and tighten the cover’s two (2) attachment screws.
Chapter 9 Maintenance 9.3.2 FP-3600T Series Replacing CA3-BLU12-01 (1) Turn the FP unit’s power OFF (i.e. disconnect the FP unit’s power cord). Remove the three (3) I/F covers, and use a Phillips screwdriver to remove the case’s seven (7) rear attachment screws and USB holder. Pivot the rear cover open, starting from the top of the unit. USB holders Rear Attachment Screws • Since the attachment screws are small, be sure not to lose them or allow them to fall inside the FP unit’s case.
FP3000 Series User Manual (3) Loosen the three (3) circuit board attachment screws. Attachment Screws (4) The circuit board is connected on one side, and hinges open. • When the FP unit's power has just been turned OFF, the circuit board chassis is still very hot! Be sure to wear gloves to prevent being burned. (5) Disconnect the backlight’s one (1) power connector.
Chapter 9 Maintenance (6) Loose the backlight unit attachment screw. Next, slide the backlight in the direction shown and lift it forward and remove it from the FP. (7) Insert the new backlight in the FP. Insert the unit by sliding it in the direction shown in step 6). (8) Connect the backlight’s one (1) power connector. Next, close the circuit board and secure the rear case in place using the attachment screws removed in steps 1), 2) and 3).
FP3000 Series User Manual 9.3.3 FP-3650T Series Replacing CA5-BLU12XGA-01 (1) Turn the FP unit’s power OFF (i.e. disconnect the FP unit’s power cord). Remove the three (3) I/F covers, and use a Phillips screwdriver to remove the case’s seven (7) rear attachment screws and USB holder. Pivot the rear cover open, starting from the top of the unit. USB holders Attachment Screws (2) The cover is fastened at the bottom, and hinges open.
Chapter 9 Maintenance (4) The circuit board is connected on one side, and hinges open. • When the FP unit’s power has just been turned OFF, the circuit board chassis is still very hot! Be sure to wear gloves to prevent being burned. (5) Disconnect the backlight’s one (1) power connector. Connector (6) Loose the backlight unit attachment screw. Next, slide the backlight in the direction shown and lift it forward and remove it from the FP.
FP3000 Series User Manual (7) Insert the new backlight in the FP. Insert the unit by sliding it in the direction shown in step 6). (8) Connect the backlight’s one (1) power connector. Next, close the circuit board and secure the rear case in place using the attachment screws removed in steps 1), 2) and 3). • Be sure not to pinch or cut any of the FP unit's internal wiring when closing the case. • If any of the attachment screws become misplaced, check to be sure that they have not fallen inside the FP.
Chapter 9 Maintenance 9.3.4 FP-3710T Series Replacing CA3-BLU15-01 and CA7-BLU15-01 (1) Turn off the FP unit’s power supply. Remove the eight (8) cover attachment screws. (2) Remove the FP unit’s rear cover. (3) Remove the cable from the Inverter Insulation Sheet, and then free the cable from the cable clamp. Next, disconnect the cable connector from the Inverter board’s backlight connector.
FP3000 Series User Manual (5) Pull out the cable in the direction shown by the arrow. The Backlight Unit comes out from the Backlight Unit Insertion Point. Backlight Unit Point Cable Backlight Unit • The entire backlight unit should be changed, not just the backlight. (6) Insert the new backlight unit into the backlight holder. (7) Secure both backlights in place using the backlight screws. The necessary torque is 0.147N•m (1.5kgf•cm).