Chapter 4 Maintenance
4-7
Preparation
Please have the following ready beforehand.
Replacement backlight
One pair of clean (preferably new) cotton gloves.
Phillips screwdriver (no.2)
4.5.1 PS-3710A Series
Be sure to wear gloves when exchanging the backlight, and follow the following procedures.
(1) Turn OFF the power switch of the PS-A and remove the power cable.
(2) Remove the PS-A unit from the equipment (panel etc.) to which the unit has been incorporated, and
place the PS-A unit on a flat, level surface facing the display face downwards.
(3) Remove the PS-A’s rear cover.
(4) Detach the FDD unit cable and power cable from the connector, and remove the two attachment screws
to detach the FDD unit.
The appropriate replacement backlight depends on your PS-A model.
PS-A Replacement Backlight
PS3710A-T41,PS3710-T41-24V,
PS3711A-T41,PS3711-T41-24V
CA3-BLU15-01
PS3710A-T42,PS3710-T42-24V,
PS3711A-T42,PS3711-T42-24V
CA7-BLU15-01
Be sure to perform the backlight changeover on a flat, level surface. This will
prevent damage to the PS-A unit and the accidental cutting of any of its power
cord.
Be sure to protect the display surface to prevent damage during the operations.
SEE
3.2.1 Removal/Attachment the Rear Cover (page 3-6)
Attachment Screw
Power Connector
FDD unit Cable
Attachment Screw
Power Cable
Rear of FDD Drive
FDD Drive Connector